Reference Materials

A. Component Functions
1. Control Box
a. The control box is located on lower left side of
appliance, on top of the junction box.
b. There is a light located inside of the control box.
The internal light will turn green when the appliance
has reached a temperature of 200
the fire pot. and will turn red when it reaches
F (315 ° C).
o
600
c. There is also an internal blue light located in the
upper left corner of the control box. When you plug
in the appliance the blue light will automatically
start blinking 6 blinks every 10 seconds for
60 seconds and then will stop.
NOTE: Do NOT open the control box. This will void the
warranty. If you need to plug in or remove the
control box you must first unplug the appliance.
2. Convection Blower
The convection blower is mounted at the bottom rear of
the appliance. There are 2 impellers, one on each side
of the motor. The convection blower pushes heated air
through the heat exchange system into the room.
3. Exhaust Blower
The exhaust blower is mounted on the right side of
the appliance behind the right side panel. The exhaust
blower is designed to pull the exhaust from the
appliance and push it out through the venting system.
4. Feed System
The feed system is located behind the firebox and
can be removed as an entire assembly. The assembly
includes the feed motor, mounting bracket, bearing and
feed spring (auger). The hollow feed spring (auger)
pulls pellets up the feed tube from the hopper area and
drops them down the feed chute into the fire pot.
5. Fire pot
The fire pot is made of high quality ductile iron and has
a cleaning pull-out rod. The floor of the fire pot opens
for cleaning when you pull out the rod. Be sure that the
floor returns to a completely closed position or your
appliance will not operate properly.
6. Fuse
The fuse is located on the side of the junction box
above the red call light. The fuse will blow should a
short occur and shut off power to the appliance.
7. Heat Exchangers
The heat exchangers transfer heat from the exhaust
system into convection air. There are 2 clean out rods
located under the heat exchangers.
28
component, it is always AS YOU FACE THE
8. Heat Output Switch
The heat output switch is located on the lower right
o
F (93 ° C) in
side of firebox, in front of the right access panel and
to the left of the reset button. The function of the heat
output switch is to regulate the burn rates; low, medium
and high settings.
9. Hopper Switch
The hopper switch is located in the upper right hand
corner of the hopper. This switch is designed to shut
down the feed motor whenever the hopper lid is
opened.
10. Igniter
The igniter is mounted on the base of the fire pot.
Combustion air travels over the red hot igniter creating
super heated air that ignites the pellets.
11. Junction Box And Wiring Harness
The junction box is located on the lower left side of
the appliance, behind the left front access panel. The
junction box and wiring harness are replaced as one
component.
12. Power Supply
The power outlet is located on the lower left side of the
appliance on the front of the junction box. Check the
wall receptacle for 120 volt, 60 Hz (standard current).
Make sure the outlet is grounded and has the correct
polarity. A good surge protector is recommended.
13. Red Call Light
The red call light is on the side of the junction box
underneath the fuse. The function of the red call light is
to indicate that the thermostat is calling for heat.
14. Reset Button
The reset button is located on the lower right side of
firebox in front of the right access panel and to the right
of the heat output control switch. The function of the
switch is to momentarily open the thermostat circuit,
which restarts the system.
15. Thermocouple
The thermocouple is located on top of the fire pot inside
the thermocouple cover (ceramic protection tube). The
thermocouple sends a millivolt signal to the control box
indicating the preset temperatures of the green and red
lights have been obtained.
16. Thermostat
The appliance is designed to run on a 12 volt AC
thermostat. The heat anticipator, if present, should be
set on the lowest setting available.