K. Ignition Cycles
1. During each ignition cycle, it is normal to see some
smoke in the firebox. The smoke will stop once the
fire starts.
2. The convection blower will automatically turn on after
your appliance has reached the set temperature. This
blower transfers heat from your appliance into the
room, and will continue to run after the thermostat
has stopped calling for heat until the appliance has
cooled down.
3. Occasionally the appliance may run out of fuel and
shut itself down. When this happens, the red call light
will be on (Figure 10.2 on
the hopper and press the reset button (Figure 10.1
on
page
10). When you press the reset button the red
call light will go out. Release the button and the light
will come back on. You should see a fire shortly. If not,
follow Starting Your First Fire on
WARNING
Fire Risk
Do NOT operate appliance:
With appliance door open.
Fire pot floor open.
Cleaning slide plates open.
Do NOT store fuel:
Closer than required clearances to
combustibles to appliance
Within space required for loading or
ash removal.
CAUTION
HOT WHILE IN OPERATION. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS.
L. Insert Removal
In the case that service or inspection is required the
appliance may need to be removed from the wall.
1. Appliance must be unplugged before removal of
appliance is possible. Unplug the appliance from its
power source.
2. Remove insert surround from appliance, to ease the
process of removal.
3. Remove the clip from the exhaust transition from the
exhaust outlet in the back of the appliance. This is
what connects the venting to the appliance. Removal
of the clips will allow you to remove the appliance from
the wall without damaging or adjusting the venting.
4. Slide appliance from the wall and rotate either direction
as needed.
12
page
10). To restart it, fill
page
10.
M. Restarting the Appliance
Restart Process
1. When the unit has run out of fuel, add pellet fuel to
the hopper.
2. Dump the ashes and clinkers built up in the fire pot by
pulling the ash dump removal handle out several times.
Make sure clinkers have dropped into the ash pan then
return the handle to fully closed position.
3. Press the reset button; the appliance will then being its
startup sequence.
Restarting After a Power Failure
1. For an electrical disruption the appliance will start on
its own without need for priming - providing the control
system is asking for heat.
2. The appliance will always go through a normal
shutdown sequence before restarting.
N. Clear Space
NOTICE: Clearances may only be reduced by means
ap proved by the regulatory authority having
jurisdiction.
Mantel:
Avoid placing candles and other heat-sensitive ob jects on
mantel or hearth. Heat may damage these objects.
Fire Risk.
Do NOT place combustible objects in front of
the appliance. High temperatures may ignite
clothing, furniture or draperies. Maintain a
minimum clearance of 3 feet (914mm) in front
of appliance.
Fire Risk.
Keep combustible materials, gasoline and
other flammable vapors and liquids clear of
appliance.
Do NOT store flammable materials in the appliance's
vicinity.
DO NOT USE GASOLINE, LANTERN FUEL,
KEROSENE, CHARCOAL LIGHTER FLUID OR
SIMILAR LIQUIDS TO START OR "FRESHEN UP"
A FIRE IN THIS Appliance.
DO NOT BURN GARBAGE OR FLAMMABLE
FLUIDS SUCH AS GASOLINE, NAPHTHA OR
ENGINE OIL.
DO NOT USE CHEMICALS OR FLUIDS TO START
THE FIRE.
Keep all such liquids well away from the appliance
while it is in use.
Combustible materials may ignite.
7019-802H
WARNING
WARNING
04/21