INSTALLATION

Only qualified, licensed personnel should install pump and wiring.
Pump mount must:
Be located away from corrosive or flammable chemicals.
Have enough ventilation to maintain air temperature at less than the maximum
ambient temperature rating (Max. Amb.) listed on the motor model plate. If this
pump is installed in an enclosure/pump house, the enclosure must have ade-
quate ventilation and air circulation to keep the temperature in the enclosure at
or below the motor's rated ambient temperature whenever the pump is running.
Be solid - Level - Rigid - Vibration free - Non-combustible. (To reduce
vibration and pipe stress, bolt pump to mount.)
Allow pump suction inlet height to be as close to water level as possible.
Allow use of short, direct suction pipe (To reduce friction losses).
Allow for gate valves in suction and discharge piping.
Have adequate floor drainage to prevent flooding.
Be protected from excess moisture.
Allow adequate access for servicing pump and piping.
Fire and burn hazard. Modern motors run at high temperatures.
To reduce the risk of fire, do not allow leaves, debris, or foreign matter to col-
lect around the pump motor. To avoid burns when handling the motor, let it
cool for 20 minutes before trying to work on it.
NOTICE: Use Teflon tape or Plasto-Joint Stik
for making all threaded
1
connections to the pump. Do not use pipe dope; pipe dope will cause stress
cracking in the pump.
NOTICE: Pump suction and discharge connections have molded in thread
stops. DO NOT try to screw pipe in beyond these stops.
Teflon Taping Instructions:
Use only new or clean PVC pipe fittings.
Wrap male pipe threads with one to two layers of Teflon tape. Cover entire
threaded portion of pipe.
Do not overtighten or tighten past thread stop in pump port!
If leaks occur, remove pipe, clean off old tape, rewrap with one to two addi-
tional layers of tape and remake the connection.
NOTICE: Support all piping connected with pump!