N
nOTe:
When installing your towel radiator, make
sure it is not resting on the blower or on its
infra-red receiver (see figure ③).

2.2 Choosing the position of the remote control

The remote control must under all circumstances be situated in the same room
as your towel radiator, with a maximum distance of 8m. You should preferably position
the remote control in direct line of sight, uninterrupted by any obstacle (wall, furniture,
etc.) to ensure that the infra-red signal is received correctly.
It can be secured to the wall or placed on the base provided (see chapter 3.1.1).
Before securing it in place, and after making the electrical connection of your
towel radiator, run an operating test. Make sure there are no objects likely to disrupt
signals between the remote control and the infra-red receiver on the towel radiator.

2.3 Connecting the appliance

InTrOdUCTIOn:
The technical specifications of your radiator are shown on its nameplate.
Please note these down before installing it and before requesting any after-sales
assistance.
The electricity supply must be protected by a residual current device with a
maximum of 30mA, especially when installed in a room containing a bathtub or
shower.
30
IP: protection level of your appliance against the
ingress of solid foreign bodies and water spray
Voltage and power required for installation
Appliance reference number
Class II: double insulated
OF: serial number
Manufacturer code
CLASS II COnneCTIOn (frenCh mArkeT):
The appliance must be installed as described in this document and in accor-
dance with the applicable European and French standards, including CEI 60364.7.701
and NF C15-100, as well as the rules of good professional practice.
ImPOrTAnT The example shown only concerns a bathtub. For other bathroom fixtures,
please consult your installer.
The flexible cable supplied with the appliance is designed to be connected to
the mains via a junction box.
nOTe:
The addition of a plug is strictly forbidden.
ImPOrTAnT The system must be fitted with an omnipolar circuit-breaker with a
minimum contact opening of 3mm.
When connecting the appliance to the mains, you must observe:
• the voltage indicated on the nameplate;
• conventional colour coding:
– Brown: live
– blue or grey: neutral
– black: pilot wire