51 GND
58 10G_KR_RX1+
52 10G_KR_RX0+
59 10G_KR_RX1-
53 10G_KR_RX0-
60 GND
54 GND
61 10G_SFP_SCL2
55 10G_LED3_2#
62 10G_SFP_SDA2
56 10G_LED3_0#
63 GND
57 GND
64 N.C.
10G_KR_TX3+/10G_KR_TX3-: 10GBASE-KR port#3 Transmit output differential pair
10G_KR_RX3+/10G_KR_RX3-: 10GBASE-KR port#3 Receive Input differential pair
10G_LED0_0#: Status /Activity Indicator for LED signalling of PHY #0 controller. Active low Output Signal, +3.3V_ALW electrical level
10G_LED0_2#: Link speed Indicator for LED signalling of PHY #0 controller. Active low Output Signal, +3.3V_ALW electrical level
10G_LED1_0#: Status /Activity Indicator for LED signalling of PHY #1 controller. Active low Output Signal, +3.3V_ALW electrical level
10G_LED1_2#: Link speed Indicator for LED signalling of PHY #1 controller. Active low Output Signal, +3.3V_ALW electrical level
10G_LED2_0#: Status /Activity Indicator for LED signalling of PHY #2 controller. Active low Output Signal, +3.3V_ALW electrical level
10G_LED2_2#: Link speed Indicator for LED signalling of PHY #2 controller. Active low Output Signal, +3.3V_ALW electrical level
10G_LED3_0#: Status /Activity Indicator for LED signalling of PHY #2 controller. Active low Output Signal, +3.3V_ALW electrical level
10G_LED3_2#: Link speed Indicator for LED signalling of PHY #2 controller. Active low Output Signal, +3.3V_ALW electrical level
EXT_MDIO_I2C_SEL: Output selection signal for the PHY indicating if the transfer is made by I2C mode (signal tied to GND) or by MDIO mode (signal tied to
+3.3V_ALW)
10G_SFP_SCL[0:3]: I2C clock signal of the 2-wire management interface used by the10GbE controller to access the management registers of an external Optical
SFP Module
10G_SFP_SDA[0:3]: I2C data signal of the 2-wire management interface used by the10GbE controller to access the management registers of an external Optical
SFP Module
10G_INT[0:3]: Interrupt input signal from copper PHY or optical SFP Module to the 10GbE controller
OCP_SMB_CK: SM Bus control clock line for OCP System Management. Bidirectional signal, +3.3V_RUN electrical level
OCP_SMB_DAT: SM Bus control data line for OCP System Management. Bidirectional signal, +3.3V_RUN electrical level
CCOMe-C79
CCOMe-C79 - Rev. First Edition: 1.0 - Last Edition: 1.0 - Author: A.R. - Reviewed by E.S. Copyright © 2021 SECO S.p.A.
Signals Description:
10G_KR_TX0+/10G_KR_TX0-: 10GBASE-KR port #0 Transmit output differential pair
10G_KR_RX0+/10G_KR_RX0-: 10GBASE-KR port #0 Receive Input differential pair
10G_KR_TX1+/10G_KR_TX1-: 10GBASE-KR port #1 Transmit output differential pair
10G_KR_RX1+/10G_KR_RX1-: 10GBASE-KR port #1 Receive Input differential pair
10G_KR_TX2+/10G_KR_TX2-: 10GBASE-KR port #2 Transmit output differential pair
10G_KR_RX2+/10G_KR_RX2-: 10GBASE-KR port #2 Receive Input differential pair