Status (Optional) - Riello RL 70 HS Manual

Light oil burner two stage operation
Table of Contents

Advertisement

Available languages

Available languages

STATUS
(optional)
Assembly
1
4
2
LED flashing
LED illuminated
Time in seconds
Burner start cycle terminated
(A)
1 Status
2 Connector
3 Bracket of the burner
4 Fixing screws
3
D3057
16
STATUS
Accessory available on request.
See page 2.
ASSEMBLY
The burners are preset to accept the Status. To
assemble, proceed as follows:
-Connect Status 1) using connector 2) fitted on
the bracket 3).
-Fasten Status to the bracket using the screws
4) supplied with the kit.
The STATUS unit has three functions:
1 - BURNER OPERATING HOURS AND THE
NUMBER OF FIRINGS ARE SHOWN ON DIS-
PLAY V
Total operating hours
Press button "h1".
2nd stage operating hours
Press button "h2".
1st stage operating hours
Total hours - 2nd stage operating hours
Number of firings
Press button "count".
Resetting operating hours and number of firings
Press the three "reset" buttons simultaneously.
Non-volatile memory
The operating hours and the number of firings
will remain in the memory even in the case of
electrical power failures.
2 - INDICATES THE TIMES RELATIVE TO THE
FIRING STAGE
The leds illuminate in the following sequence,
see fig. A:
WITH CONTROL DEVICE TR CLOSED:
1 - Burner off, TL open
2 - Control device TL closed
3 - Motor start:
seconds count starts on read-out V
4 - 1st stage valve energized
5 - 2nd stage valve energized:
seconds count stops on read-out V
6 - 10 seconds after stage 5 the code I I I I will
appear on the read-out: this indicates that the
starting phase is terminated.
WITH CONTROL DEVICE TR OPEN:
1 - Burner off, TL open
2 - Control device TL closed
3 - Motor start:
seconds count starts on read-out V
4 - 1st stage valve energized
7 - 30 seconds after stage 4:
seconds count stops on read-out V
8 - 10 seconds after stage 7 the code I I I I will
appear on the read-out: this indicates that the
starting phase is terminated.
The times, in seconds, shown on read-out V, in-
dicate the succession of the various starting
stages described on page 12.
3 - IN THE CASE OF BURNER MALFUNC-
TIONS, THE STATUS PANEL INDICATES THE
EXACT TIME AT WHICH THE FAULT OC-
CURRED.
There are 3 possible combinations of illuminated
leds, see fig. (B).
For the causes of the malfunction refer to the
numbers shown between brackets; see the leg-
end on page 15 for interpretation of the numbers.
D477
1 . . . . . . . . . . . (9 ÷ 10)
2 . . . . . . . . . . . (11 ÷ 33)
3 . . . . . . . . . . . (32)
Key to symbols (STATUS)
=Power present
=Fan motor blocked (red)
=Burner lock-out (red)
=2nd stage operation
=1st stage operation
= Load level reached (Stand-by),
D478
LED: ON (STATUS); OFF (LED
PANEL)

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Rl 100 hs3092047

Table of Contents