Commissioning; Initial Start-Up - Bosch Rexroth HQ 2/C-H Assembly Instructions Manual

Hide thumbs Also See for Rexroth HQ 2/C-H:
Table of Contents

Advertisement

8 Commissioning

8.1 Initial start-up

Sudden movements, falling workpiece pallets
Risk of injury caused by sudden movements and falling objects.
Make sure that the product has been installed properly by qualifi ed personnel
(see page 8) before commissioning it.
Malfunctions due to incorrect assembly and start-up
The product can be damaged and its service life shortened.
Commissioning requires basic mechanical, pneumatic and electrical knowledge.
The product may only be commissioned by qualifi ed personnel (see page 8).
• Before fi rst use or re-commissioning of a conveyor system, run a risk assessment in
accordance with DIN EN ISO 12100.
• Before initial commissioning, make sure there are no protruding or sharp-edged
parts that may be a hazard to personnel working or moving in the area.
• According to EU Machinery Directive 2006/42/EC, you must equip the transfer
system with EMERGENCY STOP devices.
• The surfaces of motors and gears can reach temperatures of over 65 °C under
certain load and operating conditions. In these cases, you must comply with the
appropriate design measures (protective measures) or the corresponding warning
signs of the applicable accident prevention regulations (UVV)!
• Make sure that all the electrical and pneumatic connections are either in use or
covered. Make sure that all screw connections and plug-in connections are properly
seated. All relevant protective covers must be fi tted.
• Only inspect and adjust continuous conveyors that are in motion or operation when
the guards are in place.
• Note DIN EN ISO 13857 when you remove or replace safeguards and/or nullify a
safety guideline.
• Test runs with open paneling should only be performed by a person with
appropriate knowledge and experience using hold-to-run devices, and if there is no
possibility of interference from other switching devices.
• Only start up the product if all safety equipment has been installed in the system
and is functional.
• Only start up a product which has been completely installed.
3 842 358 792/2016-12, Material and information fl ow technology: HQ 2/C-H, HQ 4, Bosch Rexroth AG
Commissioning
CAUTION
NOTE
37/64

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth hq 43 842 999 0023 842 998 035

Table of Contents