4. Routing and terminating coaxial cable(s)
Fit the extension cable to the antenna. Route the coaxial cables to the radio equipment, taking care to
observe applicable bend radii and avoiding running them adjacent to any existing wiring or fouling any
moving components. If exposed it is good practice to waterproof the RF connector joint with a
weatherproof electrical tape (self amalgamating type is recommended) allowing a significant overlap of
each turn and ensuring that the overlap is in the opposite direction to predicted water fall. If required the
coaxial cables should be fitted with properly earthed in line surge arrestors before connecting the
antenna to the radio equipment.
5. Pole Mounting using the Adjustable Bracket
Check the comms cables:
• Carry out VSWR check, the VSWR should measure <2.5:1 in transmit bands.
6. Notices
DO NOT
• operate the transmitter when someone is within 1m (3'3") of the antenna.
• operate the equipment in an explosive atmosphere.
• attempt to install the antennas without the proper safe equipment to access the install location.
• install the antenna near power lines.
• chew parts or put them in mouth, keep away from unsupervised children.
• install the antenna in such a way that it may fall and cause injury.
European Waste Electronic Equipment Directive 2002/96/EC
Waste electrical products should not be disposed of with household waste. All electronic products with the
WEEE logo must be collected and sent to approved operators for safe disposal or recycling. Please recycle
where facilities exist. Many electrical/electronic equipment retailers facilitate "Distributor Take-Back
scheme"for household WEEE. Check with your Local Authority or electronic retailers for designated
collection facilities where WEEE can be disposed of for free.
Directive 2011/65/EU (RoHS 2)
RoHS 2 compliance is declared per Directive 2011/65/EU and its subsequent amendments with exemption 6.c
applied.
REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals, EC 1907/2006)
This product contains Lead (CAS No. 7439-92-1) which is classified as an SVHC (Substance of Very High
Concern) as being toxic to reproduction under Article 57c. of REACH. Do not chew parts or put them in