• When the balance is unloaded the saved taring value is displayed with
negative sign.
• To delete the stored tare value, remove load from weighing pan and
press the TARE button.
• The taring process can be repeated any number of times, e.g. when
adding several components for a mixture (adding). The limit is reached
when the taring range capacity is full.
• Numeric input of the tare weight (PRE-TARE), see chap. 10.1.2.2

8.4 Underfloor weighing

Objects unsuitable for placing on the weighing scale due to size or shape may be
weighed with the help of the flush-mounted platform.
Proceed as follows:
Switch off the balance.
Open closing cover (1) at the balance bottom.
Place weighing balance over an opening.
Completely screw-in the hook
Hook-on the material to be weighed and carry out weighing.
• Always ensure that all suspended objects are stable enough to hold the desired
goods to be weighed safely (danger of breaking).
• Never suspend loads that exceed the stated maximum load (max) (danger of
breaking)
Always ensure that there are no persons, animals or objects that might be damaged
underneath the load.
After completing the underfloor weighing the opening on the bottom of the balance
must always be closed (dust protection).