Pos Output Limit
Some applications work best when the maximum output is
limited to some value less than the maximum possible value.
This function allows the user to set that value, as a percent of
maximum.
Range of values:
0-100%
Default choice or value:
100%
Ratio Multiplier
This function allows the user to set the ratio multiplier which is
used when the ratio function is invoked. The ratio function
allows the instantaneous output to be multiplied and set to that
value when the Ratio contact is closed. If the product is greater
than the maximum possible, the product is set to maximum.
List of choices:
N/A
Range of values:
0.1X to 10.0X
Default choice or value:
2.0X
PowerOnTens Mode
This function allows the user to choose whether the controller
will come up with tension On or Off when power is first applied
to it.
List of choices:
Off
On
Default choice or value:
Off
ExtTens On/Off
When activated this function will allow an external input to turn
tension mode On or Off. Off prevents the external input from
having an effect, while On will allow the external input to have
its effect. This function must be set to On when the optional
tension On/Off switch is used with P version controllers.
List of choices:
Off
On
Default choice or value:
Off
TensOffByTLSHI
When activated, a TLS Hi condition will cause tension to be
turned Off.
List of choices:
Off
On
Default choice or value:
Off
Disp Update Time
This function allows the user to set the interval at which the
display is updated.
List of choices (sec):
0.5, 1.0, 2.0, 3.0, 4.0, 5.0
6.0, 7.0, 8.0, 9.0, 10.0
Default choice or value:
0.5
SerialCommSource
The controller is capable of communicating with a notebook
computer (running WebHandlerLink software) or a host
computer. These devices have different command sets. This
function allows the user to select which software interface is to
be used.
List of choices:
WebHandlerLink
Default choice or value:
WebHandlerLink
SETUP MENUS
Host
continued. .
Neg Output Limit
Some applications work best when the minimum output is
limited to some value less than the minimum possible value.
This function allows the user to set that value, as a percent of
the negative maximum (-100%). This function can only be used
when Output Range is set to -V to +V..
Range of values:
Default choice or value:
Set Ratio Delay
This function sets the amount of time which must elapse
between the time the Ratio contact is opened, and the time
normal control output is restored. Note that this delay is not
associated with entering the Ratio feature, only leaving it.
List of choices:
Range of values:
Default choice or value:
PowerOnControlMd
This function allows the user to choose whether the controller
will come up in Manual or Automatic control mode when power
is first applied to it.
List of choices:
Default choice or value:
TensOffByTLSLO
When activated, a TLS Lo condition will cause tension to be
turned Off.
List of choices:
Default choice or value:
TensOffByESTOP
When activated, an Emergency Stop condition will cause
tension to be turned Off.
List of choices:
Default choice or value:
Func TimeoutTime
Allows the user to choose the amount of time which must
elapse before the controller reverts from Function mode back to
the default screen. This may be helpful if the user tends to
leave the controller in a function.
List of choices:
Default choice or value:
Set Tension Trim
When Control modes SpeedFollowTTrm or SFDiaCompTenTrm
are used, the overall output provided by Line Speed and Roll
diameter needs some amount of Tension Trim output provided
by the PID controller because of tension changes. This function
allows the user to adjust the amount of that PID output.
Range of values:
Default choice or value:
60
-100-0%
-100%
N/A
0.1 sec to 10.0 sec
1.0 seconds
Manual Mode
Auto Mode
Auto Mode
Off
On
Off
Off
On
Off
10 sec., 20, 30, 40, 50, 60, Off
Off
0-100%
10%