Inspection And Maintenance - Viega 6 PlusPress Instructions For Use Manual

Pressgun machine with rechargeable battery and bluetooth interface
Table of Contents

Advertisement

3.8.3

Inspection and maintenance

Maintenance label
2 0 X X
Fig. 7: Variants of the maintenance label
(example representation)
Maintenance interval
Pressgun 6 PlusPress machine with rechargeable battery and Bluetooth interface
The functional safety and permanent leak tightness of the Viega press
connector systems depend primarily on the functional and operational
safety of the Viega system press tools, which comprise the Viega press
machine plus Viega system press jaw, ring, chain, and hinged adapter
jaw. The Viega press tools were developed and adapted specifically for
use with the Viega press connector systems. Viega does not check
whether these system press tools can be used for pressing other manu‐
facturers' systems. In particular, no statement can be made on whether
it is possible to create permanently leakproof connections in this way.
NOTICE!
Do not attempt to carry out repairs yourself. Have repairs
carried out only by authorised service partners.
Top: Version 1
n
Bottom: Version 2, from 2019, with annually changing colour shade
n
The maintenance interval is 40,000 pressings or 4 years, whichever
occurs first. The press machine has a label showing the date when the
next regular maintenance is due.
Additionally, the press machine is equipped with an LED display which
flashes after 40,000 pressings to indicate that maintenance is due.
The safety shutdown will occur after a further 2,000 pressings.
The safety shutdown occurs after 42,000 pressings. Send
the press machine to your nearest service partner for
inspection and maintenance.