Status / description of problem
1
The press machine is switched off.
2
The press machine is ready for operation.
3
The internal memory of the press machine is
almost full to capacity. The data on the last
pressings (maximum 1000) were unable to be
saved online.
4
The press machine is in standby mode.
5
The number of pressings per service interval
has been reached (40000).
6
The press machine has made 42000 pressings.
The safety shutdown is activated.
7
The press machine has a fault.
8
Press machine and/or rechargeable battery is
outside the recommended temperature range.
9
Retaining bolt not correctly closed.
10
Battery charge too low.
11
The press machine is connected (Service
mode).
12
Briefly illuminated, Smart Cycle is activated.
Pressgun 6 PlusPress machine with rechargeable battery and Bluetooth interface
Fig. 6: Colour combinations of status LEDs
Solution
Connect the press machine connected to the
app using Bluetooth®. Connect the end device
to the Internet to transmit the data.
Send the press machine to your nearest service
partner for inspection and maintenance.
Note: The safety shutdown occurs after a fur‐
ther 2,000 pressings.
Send the press machine to your nearest service
partner for inspection and maintenance.
Remove and re-insert the rechargeable battery.
If the LED continues to illuminate, send the
press machine to your nearest service partner
for inspection and maintenance.
Bring the press machine to the recommended
temperature range in a well-ventilated environ‐
ment (-5°C to 50°C).
Slide the retaining bolt in fully (up to the lock).
Charge or replace the battery.
Switch on/off the function in the app.