Controller Check - Omron YSC-8361 Instruction Manual

Ac servo system
Table of Contents

Advertisement

ERROE
DESCRIPTION
CODE
PEDAL
Pedal warning
CARE
Safe Switch problem
Machine button
KEY1
warning
E101
High AC voltage fault
E103
High Bus voltage fault
Bus current overload
E106
E107
Encoder/Synchronizer
E110
fault
Software Update
E190,E290
Error
E191,
Software Update
E291
Error
E193,
Software Update
E293
Error
Software Update
E294
Communication Error
Software Update
E199
Error
Communication
E900
problem

1. Controller Check

Press hold
during power on, it will display "TEST" and then enter the Check
interface. Diplay A display check index, the else display contents.
1.1 Pedal
1.2 Synchronizer
Motor blocked
SOLUTION
-
Check or replace the pedal
-
Pedal not connected
-
Do not pedal yet
-
Check the Safe Switch
-
Replace the safe switch
-
Do not press machine button
-
Replace the buttons
-
Check mains voltage
-
Stabilize mains voltage
-
Use generator
-
Check mains voltage
-
Stabilize mains voltage
-
Use generator
-
Check the encoder and motor
-
Replace the encoder
-
Replace the motor
-
Eliminate stiff movement in the machine
-
Replace the encoder
-
Replace the motor
-
check or replace the synchronizer for a
belt-drive machine
-
check or replace the encoder for a
direct-drive machine
-
Software update
-
Replace the control
-
Software update
-
Replace the control
-
Software update
-
Replace the control
-
Software update
-
Replace the control
-
Software update
-
Replace the control
-
Restart the control
-
Replace the control
14