6.6 Lower thread counter
SN F6:display how much the lower thread is remaining
7. PARAMETER
NSTRUCTION
I
7.1 Setting parameter
Press
Display E shows the parameter type, press "E+" and "E-" key to change it.
Display F, G show the parameter index, press "F+", "F-", "G+", "G-" key to change it.
Displays A, B, C, D show the parameter value, press the keys under them to change it.
For example, figure 4:parameter index is 1, type is P, value of "S01" is 2000, the nixie
tube will blink when change the value. Press
and return to sewing interface.
7.2 Get the permission of setting o type parameter
Only S, T and A type parameter can be select normally, if you want to change
the O type parameter, you must press
when panel shows『DO EN』, you get the permission successfully.
7.3 Parameter solidifying
If the operator want to change some parameter's default value, then select the
parameter, press
default value has been changed.
7.4 Resumine parameter through one-key default
Select any parameter in parameter interface,
default value. The display will be twinkling if the parameter is modified, use
to confirm or
7.5 Controller recovery
Resume the default value of all parameters
Set parameter O17 to "ON", turn on the power again, after twinkling of
"INIT" finished, all parameters have been default value themselves
Restore Factory Defaults
Set parameter O51 to "ON", turn on the power again.
to enter the parameter Interface.
figure 4: the parameter interface
maintain a moment, after 『SD OK』 displaying, the
to cancel the change
to confirm, press
key when switching power on,
can be used to recall the
8