System Wiring - Emerson White-Rodgers 36H Series Installation Instructions Manual

Combination gas valve
Table of Contents

Advertisement

Available languages

Available languages

SYSTEM WIRING

REFER TO AND FOLLOW THE APPLIANCE MAN-
UFACTURER'S WIRING DIAGRAM. REFER TO
FIG. 4 AND 5 FOR TERMINAL IDENTIFICATION.
These valves are shipped with an external jumper
installed for non-piloted gas applications.
• For non-piloted gas applications HSI and DSI,
connect common wire to (C) terminal and hot
wire to external jumper (MP) terminal
(see fig. 4 and 5).
All wiring should be installed in accordance with local and national electrical codes and ordinances.
Always check that the electrical power supply used agrees with the voltage and frequency shown on
the gas control.
"
3/16
GROUND
TERMINAL
ON/OFF SWITCH
TERMINAL – M (MAIN)
TERMINAL –
P (PILOT/REDUNDANT)
TERMINAL – C (COMMON)
COMMON
C
PILOT
P
MP
MAIN
M
EXTERNAL
JUMPER
Figure 5. Simplified Gas Valve Internal Wiring and Terminal Identification
1.13
1.63
1.375
3.98 INLET TO
OUTLET
TERMINAL – HI (2ND STAGE COIL)
Figure 4. Features and Terminal Identification
4.20 R
ON/OFF
SWING RADIUS
SWITCH
PILOT
REDUNDANT
VALVE
3.77
MODELS ONLY
1.375
1.20
CENTERLINE OF
INLET & OUTLET
• For proven/intermittent pilot gas applications
such as intermittent pilot or spark-to-pilot sys-
tems, remove the external wire jumper from the
main (M) and pilot (P) valve terminals and con-
nect wires accordingly (see fig. 4 and 5).
NOTE
PILOT GAS OUTLET
PLUG OR FITTING
TWO STAGE
HI
INSTALLATION
REGULATOR COVER SCREWS
(REG. ADJ. BENEATH THESE
SCREWS)
PILOT ADJUSTMENT
COVER SCREW
(PILOT ADJ. BENEATH
THIS SCREW)
MAIN
VALVE
1.63
VENT PLU
1/8"-27 NP
.88
2ND
STAGE
VALVE
.
5
.32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents