REMOTE CONTROLLER OPERATION
4
5. REMOTE CONTROLLER OPERATION
5.1. OPTIONAL LIQUID CRYSTAL REMOTE CONTROL PC-P1HE
Model: PC-P1HE
Order No.: 7E799954
Fan Speed Indicator
It Indicates the fan speed you have selected:
(High/Medium/Low)
Total Ventilatior Indicator
It indicates if Total ventilator has been selected.
A/C
only air conditioning
VENTI
only ventilation
A/C + VENTI when both have been selected
Operation Mode Indicator
Indicates the operation mode selected:
Fan, Cool, Heat, Dry, Auto (Cool/Heat)
Run Indicator (Red Lamp)
RUN/STOP Switch
MODE (Operation Mode Selection) Switch
FAN SPEED (Fan Speed Selection) Switch
Up & Down Panel Operation Switch
VENTI(Ventilator Operation) Switch
LOUVER (Swing Louver Operation) Switch
TIME (Time Setting) Switch
Increases and decreases the Set Time for timer
operation
ON/OFF TIMER Switch
Used to activate or deactivate the timer operation
CHECK Switch
RESET (Filter Reset Switch)
After cleaning the air filter, press the "RESET" button.
The filter indication
will disappear and the next filter
cleaning time is reset. It also stops the run procedure.
TEMP (Temperature Setting) Switch
T.RUN (Test Run Indication)
Check (Check Indication)
These Tests appears when "TEST RUN" or "CHECK" is
being performed
ABNML (Alarm) Indicator
"FILTER" Indicator
SET TEMP (Setting Temperature) Indicator
ON/OFF Timer (Timer Operation Indicator)
Alarm Code Indicator
"NO FUNCTION" Indicator
CENTRAL (Central Control Indicator Operation)
Indicates that central station or CS-Net is being
performed
Swing Louver Indicator
"DEFROST" Indicator
When opening the cover,
pull the cover toward the arrow direction
NOTE:
-
Do not use this system as constant temperature and
constant humidity control equipment.
-
In the case that the LOW fan speed is selected and
outdoor temperature is higher than 21°C, excessive load is
given to the compressor at heating operation.
Therefore, set the fan speed at HIGH or MEDIUM, since
safety devices may be activated.
-
When the system is started after a shutdown longer than
approximately 3 months, it is recommended that the
system be checked by your service contractor.
-
Turn OFF the main switch when the system is stopped for
a long period of time. If the main switch is not turned OFF,
electricity is consumed, because the oil heater is always
energized during compressor stopping.