 Mounting Direction
Turn the bottom of Servo Drive in the gravity direction.
Front view
 Operating Environment Conditions
The environment in which the Servo Drive is operated must meet the following conditions. The
Servo Drive may malfunction if it is operated under any other conditions.
Operating ambient temperature
Operating ambient humidity
Operating atmosphere
Operating altitude
 Ambient Temperature Control
• Operation in an environment in which there is minimal temperature rise is recommended to
maintain a high level of reliability.
• When Servo Drives are installed in a closed space, such as a box, the ambient temperature
may rise due to the heat that is generated from each unit. Use a fan or air conditioner to main-
tain the ambient temperature of the Servo Drive from under the operating environment con-
ditions.
• The Servo Drive surface may rise in temperature of 30°C above the ambient temperature.
Use heat-resistant materials for wiring, and provide a distance from any devices and wiring
that are sensitive to heat.
• The use of the Servo Drive in a hot environment shortens its lifetime.
When you use the Servo Drive in continuous operation, use a fan or air conditioner to maintain
the ambient temperature at or below 40°C.
15
Item
AC Servomotors/Servo Drives 1S-series Instruction Manual
Side view
Specifications
0 to 55°C
90% max. (with no condensation)
No corrosive gases
1,000 m max.
Gravity direction
Bottom of Servo Drive