Download Print this page
Kipor KGE12E Operation Manual

Kipor KGE12E Operation Manual

Gasoline generator
Hide thumbs Also See for KGE12E:

Advertisement

WUXI KIPOR POWER CO., LTD.
R
GASOLINE
GENERATOR
Single-phase:
Three-phase:
KGE12E
KGE12E3
KGE12EA
KGE12EA3
KGE13EA
KGE13EA3

Advertisement

loading
Need help?

Need help?

Do you have a question about the KGE12E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kipor KGE12E

  • Page 1 WUXI KIPOR POWER CO., LTD. GASOLINE GENERATOR Single-phase: Three-phase: KGE12E KGE12E3 KGE12EA KGE12EA3 KGE13EA KGE13EA3...
  • Page 3 PREFACE Thank you for your purchase of our unit, our aim is to provide a high-quality generator set to achieve customer satisfaction, and we are confident that your choice will be justified. This manual, dealing with the generator side of the unit, gives all the basic information to ensure satisfactory and reliable operation of your unit.
  • Page 4: Table Of Contents

    CONTENTS CAUTION Electrical equipment (including electrical lines and plugs connection) could not be defective. By the effect of mechanical stress, make sure to use the rubber sheathed flexible cable or analog. 1. Names of Main Parts and Components Limit length of electric line when using the extension line or distributed network is: less than 60m for cables of 1.5mm2, and less than 100m for 2.
  • Page 5: Names Of Main Parts And Components

    1. Control panel 1. The choice of the electric cable KGE12E control panel The choice of the electric cable depends on the allowable current of the cable and the distance between the load and the generator. And the cable section...
  • Page 6 7. KGE12E3 ELECTRICAL WIRING DIAGRAM (Without Electric Governing) KGE12EA/KGE13EA digital control panel Control Panel Emergency Knob Fuse Breaker Starting Switch Single Receptacle Overload Protector KGE12EA3/KGE13EA3 digital control panel Control Panel Emergency Knob Fuse Breaker Starting Switch Single Receptacle Overload Protector -23-...
  • Page 7 2. Outline drawing of gen-set 6. KGE12E3 ELECTRICAL WIRING DIAGRAM (Without Electric Governing) (DOUBLE VOLTAGE OUTPUT) -22-...
  • Page 8 5. KGE12EA3/13EA3 ELECTRICAL WIRING DIAGRAM 3. Main Technical Specification and Date Model KGE12E/EA KGE13EA Rated Frequency Rated Power Max. Power 10.5 10.5 Rated Voltage 115/230 120/240 115/230 120/240 Rated Current 73.9/36.9 79.2/39.6 87/43.5 91.7/45.8 Rated Rotation Speed r/min 3000 3600...
  • Page 9 4. KGE12E3 ELECTRICAL WIRING DIAGRAM (Without Electric Governing) Model KGE12E3/EA3 KGE13EA3 Rated Frequency Rated Power 10.5 12.5 13.8 Max. Power 10.5 11.5 13.8 Rated Voltage 400/230 416/240 400/230 416/240 Rated Current 13.7 14.6 19.2 Rated Rotation Speed r/min 3000 3600 3000 3600 Alternator model...
  • Page 10: Preparatory Steps For Operation

    3. KGE12EA/KGE13EA ELECTRICAL WIRING DIAGRAM 2. PREPARATORY STEPS FOR OPERATION 1. Environmental Requirements 1-1 Outdoors use 1) Install gasoline generator in a dry and dustless place. 2) Avoid the direct sunshine, place gasoline Generator in shade. 1-2 Indoor use 1) Use in well-ventilated areas, or vent exhaust outside and away from any building air intakes.
  • Page 11 2. KGE12E3 ELECTRICAL WIRING DIAGRAM a. The engine must be at level state when filling lube. b. Remove the filler cover (orange), refill the recommendatory oil to the upper limit of the oil scale. c. Measure the oil mass with oil gauge. In order to measure the accurate oil level, first pull out the oil gauge, clean it and put it in, then pull out and look at the oil mark, at the same time check if the lube is...
  • Page 12 If the battery is too hot(above 45 ), recharge after stopping for a while. 1. KGE12E ELECTRICAL WIRING DIAGRAM Stop charging quickly after the battery is fully charged. If connect the battery anode and cathode against, the motor may be damaged.
  • Page 13: Start And Run The Generator Set

    2. Simple trouble judge and maintain 3. START AND RUN THE GENERATOR SET DANGER Immediately stop running generator for check and repair if any abnormality is 1. According to the “Check before running” requirement, finish each check. Then found. Restart after checking and maintain. Continue running abnormal generator turn the fuel tank switch to “ON”.
  • Page 14 Note 1) It is necessary to shorten the maintenance interval when used in dirty areas.. 2) This item maintained by Kipor agent. 3) Don't pour waste oil into the sewer or the river to prevent environment pollution. The exhaust oil from generator must be stored in container. To deal with bad matter, such as fuel, oil cooling water, solvent, filter and battery, according to the local law.
  • Page 15: Stop Procedure

    P-03 Over-voltage: indicating the voltage over-high or over-low, the generator will button could stop the generator at once. (Caution: there is no emergency stop on auto-stop. the KGE12E/KGE12E3 generator, please turn the “Starting switch” to the “stop” P-04 Generator set overload: indicating the generator overload, it will auto-stop. position.
  • Page 16: Lon-Term Storage

    5. LONG-TERM STORAGE 6. CONTROL PANEL FUNCTION If store the generator sets for long periods, please store the gen-sets in the dry, 1. Button function clean and ventilated places. Store as following: Setting of various electric parameters display in circle 1) Stop engine after engine been running for three minutes.
  • Page 18 KGE12E3 ELECTRICAL WIRING DIAGRAM KGE12E3 ELECTRICAL WIRING DIAGRAM...
  • Page 19: Periodic Maintenance And Service

    KGE12E ELECTRICAL WIRING DIAGRAM KGE12E ELECTRICAL WIRING DIAGRAM...

This manual is also suitable for:

Kge12eaKge13eaKge12e3Kge12ea3Kge13ea3
Save PDF