Start And Run The Generator Set - Kipor KGE12E Operation Manual

Gasoline generator
Hide thumbs Also See for KGE12E:

Advertisement

2. Simple trouble judge and maintain
DANGER
Immediately stop running generator for check and repair if any abnormality is
found. Restart after checking and maintain. Continue running abnormal generator
may cause unexpected serious accidents.
Fault
Reason
Battery is low or no power
Battery unclamped or rut
Starter motor
The battery and starter motor connection is disconnected.
doesn't start
Starting switch badness
Starter motor fault
No fuel
Starter motor
run, but not
Fuel pipe walled up or flat
start
Air in the fuel pipe
Gap is not appropriate
Ignition system
Spark plug
is abnormal
carbon lay-down
Overflow
Fuel system
Walled up or damaged
Carburetor
is abnormal
throttle valve is abnormal
Engine stops
Oil is not enough
because of low
Oil pressure switch badness
oil pressure.
Engine
Abnormal voice
Abnormal
Bad bearing
Alternator
noise
Fasten bolt loose
Engine coverAbnormal voice
Check around
The lube is not appropriate
Overheat
Overload
Bad breaker
Break
badness
Load circuit short
Higher Fuel
The tighten ordain bolt leakage
consumption
Carburetor
Carburetor damaged
engine
Cylinder head combustion chamber carbon laydown
Engine
deflagration
Cylinder head gasket damaged
Cannot
Air filter walled up
reach
AVR badness
the rated
power
Low rotation speed
-
Troubleshooting
Charge or replace
Install the terminal after cleaning or replace
Repair or replace
Repair or replace
Repair or replace
Refill fuel
Clean or replace
Empty air
Regulate
Clean or replace
Regulate
Open and clean or replace
Check and regulate
Refill oil
Replace switch
Repair
Replace
Tighten
Repair
Move sundries from air outlet
Replace
Drop to rated load
Contact with service
Check
Tighten
Replace
Open and clean
Replace
Clean or replace
Contact with dealer
Improve the rated speed
-

3. START AND RUN THE GENERATOR SET

1. According to the "Check before running" requirement, finish each check. Then
turn the fuel tank switch to "ON".
2. Disconnect all the outer loads on the AC receptacle.
3. Turn the breaker to the "OFF" position, draw the chock handle, and turn off the
choke.
4. Turn the "starting switch" key to the "RUN", the generator is in the standby
mode after the "digital control panel" display initial interface.
5. Turn the "starting switch" key to the "START", loose the key after generator
started, and the key will return to "RUN" automatically. In the first time, if start fail,
restart it after 30seconds.
6. Run the generator set
Loose "starter switch" key after starting, push the throttle handle back to it's
position, then the generator will be in the automatic running state.
7. After making sure the generator voltage, frequency and other running state
meet the using require, close the main breaker, then it can supply output power to
load.
CAUTION
Preheat generator three minute without load after the set starting, then running
with load
The new generator set have a running-in period, the period is the initial 20
hours, only with 50% load during the running-in period, or it will shorten the set
life.
8. Checks during the running
1) Whether there is abnormal sound or vibration;
2) Whether the engine misfires or runs rough;
3) Check the color of the exhaust. (Is it black or too white?)
If you notice any of the above-mentioned phenomenon happened, stop the
engine and find out the fault cause or contact with our agents.
CAUTION
If the engine has been running, the muffler will be very hot. Be careful not to
touch the muffler.