Page 3
PREFACE Thank you for purchasing a Kipor Generator. This manual covers the operation and preventive maintenance of the IG4300 generator with EPA and California Air Resources Board (CARB) certification if so designated. All information in this publication is based on the latest product information available at the time of printing.
Page 4
The portable generator is not meant to be used as a permanent back-up power system for the home. A permanently installed stationary generator is designed to be safely used for this specific purpose. Indicates a strong possibility of severe personal injury or death if instructions are not followed.
1. SAFETY INSTRUCTIONS Our generators are designed to give safe and dependable service if operated according to these instructions. Read and understand the owner's manual before operating the generator. Failure to do so could result in personal injury or equipment damage. Exhaust gas contains poisonous carbon monoxide.
Page 8
To ensure safe operation: Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped. Keep away from smoking materials, sparks and other sources of combustion when refueling the generator. Always refuel in a well-ventilated location.
2. COMPONENT LOCATIONS 2.1 Outside view Carbon Canister Spark Plug Oil Dipstick Control Panel Service Door Inlet Battery Air Filter Fuel Level Indicator Fuel Filler Cap Air Quality Index Starter Grip Air Exhaust Muffler Warning...
2.3 Serial Number Location The engine serial number is stamped on the engine block to the left of the oil drain plug. In most cases the battery will have to be removed to view it clearly. Refer to this number when ordering parts or making technical inquiries.
3. PRE-OPERATION CHECK Be sure to check the generator on a level surface with the engine stopped. Under no circumstances can this generator be installed in an enclosed compartment. 3.1 Engine Oil Level Using non-detergent oil or 2-stroke engine oil could shorten the engine's service life.
Running the engine with insufficient oil can cause serious engine damage. The Low Oil Alarm System will automatically stop the engine before the oil level falls below a safe limit. However, to avoid the inconvenience of an unexpected shutdown, it is still advisable to visually inspect the oil level regularly.
Gasoline containing alternate fuels: If you decide to use a gasoline containing ethanol, be sure its octane rating is no lower than the specification. Do not use a blend that contains more than 10% ethanol. Do not use any gasoline containing methanol.
"ON" position, then wait for 10 to 20 seconds before starting the engine. 4.1 Starting Procedure 4.1(a) Turn the fuel valve lever to the ON position. IG4300 Fuel Switch...
Page 16
4.1(b) Pull the choke knob out to the CLOSED position Do not use the choke if the engine is already warm or the ambient air temperature is high. Choke knob 4.1(c) Insert the engine key and turn the engine switch to ON position. Engine switch...
Page 17
4.1(d) Electric Start: turn the engine switch to the START until the engine has started. Do not operate the starter for more than 10 seconds. Manual Start: pull the starter grip lightly until resistance is felt then pull the starter grip briskly toward the arrow as shown below.
4.2 High altitude operation At high altitude, the standard carburetor air-fuel mixture will be excessively rich Performance will decrease, and fuel consumption will increase. High altitude performance can be improved by installing a smaller diameter main fuel jet in the carburetor.
5. GENERATOR USE 5.1 Warnings and Cautions To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy cable between the generator's ground terminal and an external ground source. Connections for standby power to a building's electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes.
When an extension cable is required, make sure you use the proper size and length. 16 Gauge Cords- Any 16 gauge cord between 0 and 100 feet long will adequately handle tool and appliance • loads up to 10 amps 14 Gauge Cords- a 14 gauge cord between 0 and 50 feet long will adequately handle loads between 10 and •...
disconnect all appliances disconnected immediately and have them inspected by a qualified electrician before attempting to use them again. Do not attempt to operate appliances if the ground fault circuit interrupter reset button pops out repeatedly during use. Only the ground fault circuit interrupter receptacle provides ground fault protection. 5,3 Voltage Selection Switch The voltage selection switch has two positions: AC120V and AC120/240V.
Be sure that all appliances are in good working order before connecting them to the generator. If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn off the generator engine switch immediately. Disconnect the appliance and examine it for signs of malfunction. 5.5 Output and Overload Indicators The green output indicator light will remain on during normal operating conditions.
Before connecting an appliance to the generator, check that it is in good order, and that its electrical rating does not exceed that of the generator. . When an electric motor is started, both the overload indicator light and the output indicator light may go on simultaneously. This is normal if the overload indicator light goes off after about four seconds.
5.7 Air Conditioner Operation For best results, the SMART throttle switch should be in the off position. Bring the generator to a normal operating temperature before applying the air conditioning load. Always allow a 2 minute wait period when manually cycling an air conditioner off and on. A longer wait period may be required under unusually hot weather conditions.
Page 25
The battery contains sulfuric acid (electrolyte). Contact with skin or eyes may cause severe burns. Wear protective clothing and a face shield. A. If electrolyte gets on your skin, flush with water. B. If electrolytes gets in your eyes, flush with water for at least 15 minutes and call a physician.
5.9 Low oil alarm system The low oil alarm system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls below a safe limit, the low oil alarm system will automatically shut down the engine (the engine switch will remain in the ON position).
Page 27
With the voltage switch in the 120/240V position, the parameters will be different as the display looks at both 120V AC legs 1 . Total Voltage (both legs) 2. Single Voltage leg A 3. Single Voltage leg B 4. Leg A current value 5.
6. STOPPING THE ENGINE 6.1 Normal Shutdown 1. Switch off the connected equipment and disconnect from the generator. 2. Turn off the engine switch. 3. Turn the fuel valve lever to the OFF position. 6.2 Emergency Stop Turn the start switch to the OFF position. Continually stopping the generator with a load applied can lead to damage of the control module.
Carbon monoxide is a poisonous gas. The emission of fuel vapors is a source of pollution as well. The Kipor generator engine utilizes a precise air-fuel ratio and emission control system to reduce the emissions of carbon monoxide, NO , hydrocarbons, and evaporative fuel emissions.
Page 30
You can trust the replacement parts supplied by Kipor have been manufactured to the same production standard as the original parts. The use of replacement parts or accessories which are not designed by Kipor may affect the engine emission performance.
(2) Service more frequently when used in dusty conditions. (3) These items should be serviced by an authorized KIPOR service center unless the owner has the proper tools and is mechanically proficient. Refer to the KIPOR Generator and Engine shop manuals.
Oil drain bolt Oil dipstick 1. Open the left side maintenance cover. 2. Remove the oil dipstick. 3. Remove the drain bolt and drain the oil. There is a rubber plug in the bottom of the generator pan that can be removed to facilitate draining the oil. The generator will have to be raised off the ground and supported while the oil drains.
Air Filter Base Filter Element Air Filter Cover Filter EleElement 1. Open the service door. 2. Unsnap the clips and remove the air cleaner cover. 3. If the paper element is dirty or torn, replace it with a new one. Do not attempt to clean the element. 5.
5. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused. 6. Measure the plug gap with a feeler gauge. The gap should be 0.028-0.031in (0.7-0.8mm). Correct as necessary by carefully bending the side electrode.
1. Remove the generator rear cover to access the spark arrestor. 2. Remove the spark arrestor from the muffler by unscrewing the clamp. 3. Clean the spark arrestor with a stiff wire brush. 4. Replace if the wire mesh is perforated or torn. 5.
5. Remove the spark plug and pour a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil and then reinstall the spark plug. 6. Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed.
1) Turn off the fuel valve and loosen the drain screw. 2) Fuel should flow from the drain when the fuel If the engine still does not start, take valve is turned on. the generator to an authorized Kipor service center.
Page 38
AC Appliance does not operate: Is the output indicator light ON? Is the overload indicator Take the generator to a Kipor service center. light ON? Check the electrical appliance or Take generator equipment for any defects. authorized KIPOR service center.
10. SPECIFICATIONS Model IG4300 Type Inverter Rated Voltage 120/240 Frequency 60 HZ Maximum Output 4300W, 35.8A/17.9A Rated Output 4000W, 33.3A/16.7A DC Output 12V@5.0A Engine Model KG280 Engine Type 4 Stroke, overhead valve, single cylinder Displacement 277 cc Compression Ratio 8.5:1 Rated Power 5.5 HP @ 3600 RPM...
Page 42
A Wheel Assembly Installation a. Install the left and right axle plates b. Insert axle through the plate c. Install an iiner washer, the wheel, and an outer washer d. Secure with a cotter pin 1. Wheel 2. Axle 3. Cotter Pin 4.
You may be denied warranty coverage if a part has failed due to abuse, neglect, improper maintenance, or unapproved applications. You are required to bring your generator to an authorized Kipor generator dealer for repairs as soon as a problem exists. emissions...
Page 45
Kipor Generator Owner’s Manual. Additionally, coverage may be denied for the use of add-on parts, modified parts, or parts that are not equivalent to original Kipor generator parts in performance and durability.
2. As the SORE owner, you should however be aware that Kipor may deny your warranty coverage if your SORE or a part has failed due to abuse, neglect, improper maintenance or unapproved modifications.
3. A catalyst is built into the muffler to further treat the engine exhaust. 4. A secondary air injection valve adds combustion air to ignite unburned fuel in the exhaust. Contact your authorized Kipor service center to obtain the correct replacement parts and service on this system.
Page 49
Generator Frame Canister Service Door Side Carbon Canister Location Secondary Valve Gasket Bolt Muffler with Catalyst Gasket Spark Arrestor Connection to exhaust manifold...