var_SetVirtualLimits:
• Function: Determines whether the component will modify
the pillar's current virtual limits settings using the set_virtu-
alLimits command.
• Type: Boolean variable
• Default: false
var_LowerLimit:
• Function: Sets the lower virtual limit used in the set_virtu-
alLimits command.
• Type: Float variable
• Default: 0
var_UpperLimit:
• Function: Sets the upper virtual limit used in the set_virtu-
alLimits command.
• Type: Float variable
• Default: 700
16
16
Set_Info Settings
var_SetType:
• Function: Determines whether the component will modify
the pillar's current type using the set_type command. If set
to true, this will require both the pillar and communication
box to be power cycled for the changes to take effect, and
the component will exit immediately after the type is set.
• Type: Boolean variable
• Default: false
var_Type:
• Function: Sets the value of the pillar type that will be set
once the set_type command is issued. Use the get_type-
sAvailable command in the Get Info function of the compo-
nent for a list of acceptable pillar types.
• Type: String variable
• Default: "LIFTKIT-601"