Technical Data - SMA MD.IO-40 Installation Manual

I/o module
Table of Contents

Advertisement

8 Technical Data

8 Technical Data
General Data
Mounting location
Voltage supply
Mechanical Data
Width x height x depth
Ambient Conditions for Storage/Transport
Ambient temperature
Relative humidity, non-condensing
Maximum height above mean sea level
Digital inputs
Quantity
Input voltage
Cutoff frequency
Maximum cable length
Digital outputs (multifunction relay)
Quantity
Execution
Maximum switching voltage
Maximum switching current
Minimum switching current
Minimum electrical endurance when the maximum switch-
ing voltage and maximum switching current are complied
with
Bounce time
Reset time
Maximum cable length
20
MD-IO-40-IA-en-11
SMA Solar Technology AG
In the inverter
Via the inverter
60 mm x 105 mm x 33 mm
-40°C to +70°C
10% to 100%
3000 m
6
24 V
DC
30 Hz
100 m
3
Potential-free relay contacts
30 V
DC
1 A
10 mA
100000 switching cycles
5 ms
5 ms
100 m