Zip HydroTap All-In-One 89944 Installation And Operating Instructions Manual

Advertisement

Quick Links

Installation and Operating Instructions
®
Zip HydroTap All-In-One
Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms.
This Installation Instruction covers the following HydroTap residential models:
Affix Model Number Label Here
89944
HydroTap Installation and Operating Instructions - 89944 - July 2011 v1.01
Page 1 of 20

Advertisement

Table of Contents
loading

Summary of Contents for Zip HydroTap All-In-One 89944

  • Page 1 Installation and Operating Instructions ® Zip HydroTap All-In-One Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms. This Installation Instruction covers the following HydroTap residential models: Affix Model Number Label Here 89944 HydroTap Installation and Operating Instructions - 89944 - July 2011 v1.01...
  • Page 2: Table Of Contents

    Contents Read These Warnings First ......3 Installation Requirements ......4 Special tools required .
  • Page 3: Read These Warnings First

    Read These Warnings First Safety This appliance is not intended for use by persons (Including Children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance Refrigerant The HydroTap Chilling unit contains 134A refrigerant under pressure.
  • Page 4: Installation Requirements

    Read These Warnings continued is needed, follow the instructions on page 15 /16 or contact your Service Provider. Frost Protection If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not in use, do not turn off the appliance electrically.
  • Page 5: Special Tools Required

    Installation Requirements continued • Power supply 220-240 Volt AC, for connection to the heater via a 10 amp (160/125) or 15 amp (240/175) GPO. • This switch must provide all-pole disconnection and a contact separation of at least 3mm installed in accordance with wiring rules.
  • Page 6: Installation Procedure

    Installation procedure continued Step B - Installing the undersink unit NOTE : SPECIAL NOTE: The HydroTap undersink units are heavy, take note of the New hose sets supplied with the weights listed in the table on page 4. If you think you cannot lift the unit unit should be used.
  • Page 7 Installation procedure continued Connect the tap USB connector to the USB port on the undersink unit. Orient the USB plug carefully and connect, do not force the plug. Once connected, fix the cable to the wall, ensure it is away from any possible water splashes and is off the floor.
  • Page 8 Installation procedure continued Step D - Connecting the water supply To prevent sediment from entering the HydroTap at connection, flush water through the supply line thoroughly before connection to the HydroTap. Open the access door and check that the filter is in place and secure. Connect the water supply to the undersink unit using the attached flexible hose .Turn ON water and check for leaks.
  • Page 9: Operating The Mixer Tap

    Operating the Mixer tap The Mixer tap is operated as a conventional ‘Flick Mixer’ Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Lift the handle all the way up to turn the tap off. When the handle is moved to the left, the temperature is decreased and when moved to the right the temperature is increased.
  • Page 10: Mains Version Connections (Diagrams)

    161.50 SILICONE HOSE FROM STEAM VENT IN HYDROTAP UNIT TO TAP VENT OUTLET POSITION NOTE: BOILING CHILLED IF THE FLOW RATE IS WATER 240V GPO WATER TOO FAST, CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM OF THE BASE OF THE ALL-IN-ONE TAP.
  • Page 11 ALL IN ONE TAP-MAINS VERSION SILICONE HOSE FROM BOILING WATER TANK IN HYDROTAP UNIT TO TAP BRAIDED HOSE BH1 FROM MAINS SUPPLY BENCHTOP CABINET DOOR 4mm BUFFER PAD TO ENSURE VENTILATION GAP BRAIDED HOSE BH2 FROM DOMESTIC HOT WATER SUPPLY SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNIT TO TAP...
  • Page 12: Vented Version Connections (Diagrams)

    SILICONE HOSE FROM BOILING WATER TANK IN HYDROTAP UNIT TO SILICONE HOSE FROM STEAM BRAIDED HOSE BH1 VENT IN FROM MAINS HYDROTAP WATER SUPPLY TO TAP SILICONE HOSE FROM CHILLED BRAIDED HOSE BH2 WATER TANK IN FROM ALL-IN-ONE TAP HYDROTAP UNIT TO VENTURI TO TAP BRAIDED HOSE BH3...
  • Page 13 ALL IN ONE TAP-VENTED VERSION MAINS AMBIENT WATER SUPPLY (ISOLATION VALVE NOT SUPPLIED)
  • Page 14: Operating The Hydrotap

    Operating the HydroTap Blue Chilled Water Light On all the time: Press or pull lever This indicates that the temperature of the chilled water is within the usable temperature range. Flashing slowly : This indicates that the chilled water is not at the right temperature. Wait up to 20 minutes.
  • Page 15: Replacing The Filter

    Replacing the Filter The Zip HydroTap notifies when filter replacement is due. The default setting is 6000 Ltrs, but this can be set in increments of 1000Ltr from 1000Ltr to 10000Ltrs. When a filter change is due, the Change Filter light will flash white once a minute and remain so until reset.
  • Page 16 Setting the Energy Saver Timer (continued) Normal Operation (not available on HT boiling only series) Set Time To change time, press either Mode or Mode button until Set Time is on the display screen. Press Adjust button to increase time or Adjust button to decrease time.
  • Page 17: Auxiliary Fan Attachment

    Setting the Energy Saver Timer (continued) Activating ‘Sleep-when-it’s-dark’ feature This feature will automatically switch the unit into Sleep mode Option 1 when the ambient light falls below a set level. For this system to operate correctly the sensor in the tap head must be calibrated for it’s surroundings. Activation: This can only be achieved through the service mode.
  • Page 18: Boiling Safety Isolation

    Boiling Water Isolation The HydroTap if equipped with a safety mode that allows protection against accidental operation by Infirm or disabled persons. 1. On the LCD scroll through the menu to Hot Isolation. 2. Press Adjust to activate. 3. Now go to the Tap Head assembly and press the Safety Lock (3) three times rapidly, the LED’s will scroll from left to right (3) three times.
  • Page 19: Cleaning

    Cleaning Do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft cloth or brush and mild soap and water. Do not spray water over the tap as it may damage the low-voltage electronics. Undersink units must never be located near, or cleaned with water jets. Trouble Shooting Symptom Possible Cause...
  • Page 20: Warranty / Contact Information

    Registering Your Purchase Registering your Zip installation on the Zip website may help to establish date of installation should it become necessary to service the appliance under terms of the Zip warranty. To register your installation go to www.zipheaters.com and look under the heading “Register your purchase/Warranty information”, or forward the completed product registration form...