Installation; Safety; Equipment Description; Sbp 1000 And 1500 E | E Sol | E Cool - STIEBEL ELTRON SBP 1000 E Operation And Installation

Buffer cylinder
Hide thumbs Also See for SBP 1000 E:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12

installation

safety

4. Safety
The installation and commissioning should only be carried out
by contractors. During this process the installation instructions
must be observed.
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
5. Equipment description
5.1 SBP 1000 and 1500 e | e Sol | e cool
1 000 and 1500 E | E SOL | E cool
22
3
17
19
18
16
21
16
12
15
20
14
13
11
14
| sBp e | sBp e sol | sBp e cool
1
Heating flow
2
Heat pump flow
3
Connector for threaded immersion heater BGC
4
Flange for additional heat source
5
Connector for additional heat source flow 1
6
Connector for additional heat source flow 2
7
Connector for additional heat source return 2
8
Connector for additional heat source return 1
9
Heating return
10 Heat pump return
11 Drain connector
12 Internal indirect coil solar, flow (only SBP...E SOL)
13 Heat exchanger solar, return (only SBP...E SOL)
14 Protective pipe for temperature sensor, heat pump return
15 Protective pipe for temperature sensor, solar
16 Protective pipe for temperature sensor, additional
heat source
17 Protective pipe for temperature sensor, heat source 2 heat
1
pump (FCR) / cooling heat pump / additional heat source
18 Protective pipe for thermometer (on site)
3
19 Air vent valve connector
20 Type plate
2
21 Preinsulation (only SBP...E cool)
22 Lifting eyes
5.2 Standard delivery
4
5.2.1 SBP 1000 and 1500 E | E SOL | E cool
The standard delivery includes the following parts, packed in a
separate bag:
— buffer cylinder with dummy flange DN 280
— operating and installation instructions
5
— additional type plate.
5.3 thermal insulation wD SBP / wD cool
Thermal insulation, specifically designed for the buffer cylinder
6
is available as special accessory. The thermal insulation compri-
ses an outer jacket made from polystyrene, a 90 mm thick main
9
thermal insulation made from EPTS and a 20 mm thick polyester
fabric fleece layer (not for WD cool).
7
Description
WD 1000 SBP for SBP 1000 E and E SOL
10
WD 1500 SBP for SBP 1500 E and E SOL
WD 1000 cool for SBP 1000 E cool
8
WD 1500 cool for SBP 1500 E cool
5.4 Special accessories
The following components are available for the optional comple-
tion of the buffer cylinder.
Description
Threaded immersion heater BGC
Immersion heater (flanged) FCR 28/120
Immersion heater (flanged) FCR 28/180
Immersion heater (flanged) FCR 28/270
Immersion heater (flanged) FCR 28/360
Immersion heater (flanged) FCR 28/120
Immersion heater (flanged) FCR 28/180
Heating internal indirect coil WTW 28/18
Heating internal indirect coil WTW 28/23
Part no.
227592
227593
227594
227595
Part no.
075115
000694
000695
000696
001502
071332
071333
076098
076099
www.stiebel-eltron.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sbp 1500 eSbp 1000 e solSbp 1500 e solSbp 1000 e coolSbp 1500 e cool

Table of Contents