Gree GPH12AO-K5NNA1A Owner's Manual page 4

Local air conditioner
Table of Contents

Advertisement

The refrigerant
Appliance filled
with flammable
gas R290.
Before use the
appliance, read
the owner's ma-
nual first.
The Refrigerant
To realize the function of the air conditioner unit,
a special refrigerant circulates in the system.
The used refrigerant is the fluoride R290, which
is specially cleaned. The refrigerant is flammable
and inodorous. Furthermore, it can leads to ex-
plosion under certain conditions.
Compared to common refrigerants, R290 is a
nonpolluting refrigerant with no harm to the
ozonosphere. The influence upon the green-
house effect is also lower. R290 has got very
good thermodynamic features which lead t
really high energy efficiency. The units there
fore need a less filling.
WARNING
Appliance filled with flammable gas R290.
Appliance shall be installed,operated and stored
in a room with a floor area larger than 11m .
The appliance shall be stored in a room without
continuously operating ignition sources.
(for example:open flames,an operating gas app-
liance or an operating electric heater.)
The appliance shall be stored in a well-ventilated
area where the room size corresponds to the
room area as specified for operation.
The appliance shall be stored so as to prevent
mechanical damage from occurring.
Ducts connected to an appliance shall not con-
tain an ignition source.
Keep any required ventilation openings clear of
obstruction.
Do not pierce or burn.
Be aware that refrigerants may not contain an
odour.
Do not use means to accelerate the defrosting
process or to clean,other than those recomm-
ended by the manufacturer.
Servicing shall be performed only as recomm-
ended by the manufacturer.
Before install the
appliance, read
the installation
manual first.
Before repair the
appliance, read
the service ma-
nual first.
o a
2
Should repair be necessary,contact your nearest
authorized Service Centre. Any repairs carried out
by unqualified personnel may be dangerous.
Compliance with national gas regulations shall
be observed.
Read specialist's manual.
Frequency band(s) in which the radio equipment
operates: 2400MHz-2483.5MHz
Maximum radio-frequency power transmitted
in the frequency band(s) in which the radio
equipment operates: 20dBm
R290:3
This marking indicates that this product
should not be disposed with other hou-
se hold wastes throughout the EU. To
prevent possible harm to the environm-
ent or human health from uncontrolled
waste disposal,recycle it responsibly to promote
the sustainable reuse of material resources. To r-
eturn your used device, please use the return and
collection systems or contact the retailer where the
product was purchased. They can take this prod-
uct for environmental safe recycling.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gpc12ao-k5nna1a

Table of Contents