Goodman AVZC180241 Service Bulletin page 5

Crank case heater kit for inverter split systems
Table of Contents

Advertisement

TERMINAL BLOCK WITH ADAPTOR
Route Temperature switch cables through compressor cable opening
15. Ensure that the switch cables are routed through the
same jacket opening as the compressor power cables.
16. Replace the Top Panel Assy. Before securing the as-
sembly, tie wrap the fan motor cable to the coil return
tube. ENSURE TO ROUTE FAN MOTOR WIRE BE-
TWEEN COIL AND PCB PANEL.
17. Ensure all excess cable wires are properly secured
using existing wire loops.
18. Reinstall lower access panel and access tube using
existing hardware.
19. Once all components are installed, turn outdoor unit on.
Let unit cycle for 5 minutes.
20. After cycle time, turn off outdoor unit and remove the
Bluetooth Shared Data Loader (BTSDL01). Install back
PCB cover and turn outdoor unit back on.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents