9.2.

Valve

Issue
Valve disc cannot close because of
Flowing or
debris.
dripping water at
drain or brine line
Valve stem return spring is weak.
after regeneration.
Restricted drain line.
Valve will not draw
Injector plugged.
brine.
Debris is preventing complete opening
or flapper is damaged.
AC adapter or motor are not
connected.
Controller will not
regenerate
Defective motor.
automatically.
Meter clogged with debris.
Controller
regenerates at
Time of day set incorrectly.
wrong time of day.
Intermittent or
Low water pressure.
irregular brine
draw.
Defective injector.
Backwashes or
Incorrect drain controller used.
purges at
Foreign matter affecting valve
excessively low or
operation.
high rate.
Ref. MKT-IM-045 / A - 13.03.2020
Installer Manual Riversoft - Troubleshooting
Cause
Reset and recovery
Remove debris.
Replace the spring. See 8.5.7.5
Cleaning / replacing flappers, page 74.
Change drain to remove restriction.
Clean injector and screen. See 8.5.5.
Cleaning injector and injector screen,
page 67.
Check flapper, clean seat and flapper,
replace if necessary.
Connect the power source.
Replace the motor. See 8.5.7.3 Motor
and camshaft replacement, page 71.
Remove and clean the meter.
Set correct the time of day. See 5.4.
Time of day, page 46.
Set pump or pressure regulator to
maintain 1.38 bar (20 psi) dynamic at
softener's inlet.
Replace injector.
Replace with a correct size.
Remove drain control and clean ball
and seat.
79 / 90