Download Print this page
CommScope HELIAX FiberFeed HFA208 Series Installation Manuallines

CommScope HELIAX FiberFeed HFA208 Series Installation Manuallines

Fiber/copper hybrid cables

Advertisement

Quick Links

Technical Publication
Installation Guidelines – HELIAX
Fiber/Copper Hybrid Cables: HFA208 │HFA210 │HFA406
Related Support and Learning Opportunities Offered by the CommScope Infrastructure Academy
The insights and expertise contained in this manual represent just one small part of CommScope
global learning initiative. Few industries are evolving as quickly as wireless communications. Every
technological innovation impacts what happens in the field. Our customers look to the CommScope
Infrastructure Academy to make sure their technicians and installers are well trained, well-prepared,
and well-educated to take advantage of opportunities as they evolve.
Field Engineering Services (FES)
Support services, such as our Field Engineering Services (FES) Group gives customers access to
technical support where and when it is needed the most — in the field. The FES team is staffed
by an expert team of technicians who, in turn, are supported by some of the brightest and most
experienced product line managers. With all of this knowledge and support the FES offers our
customers access to hands-on, specialized training classes.
Section 1: General Specifications ..........................................................................................................02
Section 2: Breakout Procedure / DLC Connection Considerations ...................................................04
Section 3: Cleaning / Inspecting ....................................................................................................05
Section 4: Excess Cable Handling ..........................................................................................................06
Section 5: Hanger / Jacketing Removal / Grounding .................................................................................07
Section 6: Protecting Spare Fibers / Installation Check List ........................................................................08
Customer Service Center
United States and Mexico 1-800-255-1479 or 1-888-235-5732
International: +1-779-435-8579
www.commscope.com/andrew
1-800-255-1479
FiberFeed
Rooftop Solution
®
®
Bulletin # 7695778
Rev. E
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the HELIAX FiberFeed HFA208 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CommScope HELIAX FiberFeed HFA208 Series

  • Page 1 Fiber/Copper Hybrid Cables: HFA208 │HFA210 │HFA406 Related Support and Learning Opportunities Offered by the CommScope Infrastructure Academy The insights and expertise contained in this manual represent just one small part of CommScope global learning initiative. Few industries are evolving as quickly as wireless communications. Every technological innovation impacts what happens in the field.
  • Page 2: General Specifications

    534 N | 120 lbf 534 N | 120 lbf 810 N | 180 lbf Tensile Load, short term, maximum 1780 N | 400 lbf 1780 N | 400 lbf 2700 N | 600 lbf www.commscope.com/andrew • 1-800-255-1479 Bulletin # 7695778 Rev. E...
  • Page 3 1070 N | 240 lbf 1070 N | 240 lbf Tensile Load, long term, maximum 3560 N | 800 lbf 3560 N | 800 lbf Tensile Load, short term, maximum 3560 N | 800 lbf www.commscope.com/andrew • 1-800-255-1479 Bulletin # 7695778 Rev. E...
  • Page 4 Caution: Do not try to clean adapter with a standard pipe cleaner. The sleeve inner diameter of LC adapters is too small. Do not try to clean the adapter with cleaning stick if a connector is mounted in one side. Discard cleaning sticks after each use. Adapter Brush www.commscope.com/andrew • 1-800-255-1479 Bulletin # 7695778...
  • Page 5 Is It Clean Inspect Clean? Clean Connect Abrasive particles (i.e. rock dust) can cause permanent damage to the interface. If interface is scratched it cannot be repaired, it would need to be replaced. www.commscope.com/andrew • 1-800-255-1479 Bulletin # 7695778 Rev. E...
  • Page 6 Part Number: Fe-14192-IR Remove excess rip cord Apply electrical tape to protect breakout NOTE: Remember to slide identifier labels down the power conductors before trimming the cable to it’s final length www.commscope.com/andrew • 1-800-255-1479 Bulletin # 7695778 Rev. E...
  • Page 7 Ground Kit UG12158-15B4-T is a universal solution for all HFF trunk cables. Only use Tin Plated grounding kits Ground kits required at the top and bottom before entering the equipment / shelter / cabinet www.commscope.com/andrew • 1-800-255-1479 Bulletin # 7695778...
  • Page 8: Installation Checklist

    Hinweis: CommScope lehnt jede Haftung oder Verantwortung für Schäden ab, die aufgrund unsachgemäßer Installation, Überprüfung, Wartung oder Demontage auftreten. Atenção: A CommScope abdica do direito de toda responsabilidade pelos resultados de práticas inadequadas e sem segurança de instalação, inspeção, manutenção ou remoção.

This manual is also suitable for:

Heliax fiberfeed hfa210 seriesHeliax fiberfeed hfa406 seriesHeliax fiberfeed hfa208-6mc1 seriesHeliax fiberfeed hfa208-6mt2 seriesHeliax fiberfeed hfa208-6mt3 seriesHeliax fiberfeed hfa208-6sc2 series ... Show all