ABB SACE PR010/T Instructions Manual page 20

Test unit
Hide thumbs Also See for SACE PR010/T:
Table of Contents

Advertisement

Nr.
Faults
1
The POW ER-O N led is
Light-off
2
The mes sage display is not
clear
3
The display language is
incorrect
4
P roblems updating the
sof tware installed on the
P R010/T unit
5
P roblems downloading the
test report to t he PC
6
P roblems
connecting
cable t o the device under
test
ABB SACE
Troubl eshooting guide
Causes and errors
The external power supply
is disconnected
The external power supply
is disconnected f rom the
mains power supply
The O N/O FF s witch is set
to OFF
No batteries f itt ed
The batteries are
discharged
The contrast and/or
brightness setting(s) are
incorrectly adjust ed
The language setting is
incorrectly programmed
Wrong connection cable
used to connect the PC to
the P R010/ T test unit
The serial cable is not
properly connected
The P R010T unit is not
ready for Sw updating
The P R010T's time-out
elapses before the software
starts downloading from the
PC
The update file is not
selected
The wrong type of f ile is
selected
The f ile downloaded is
damaged
Wrong
connection
used to connect the PC to
the P R010/ T test unit
The serial cable is not
properly connected
The PR111-type release is
fitted with t he wrong adapter
The
PR111
damaged
An
Isomax
the
connected
to
circuit breaker, or vice versa
The cable is connected the
wrong way round
SACE PR010/T
Checks and remedi es
Power up t he unit with the
power supply provided by
ABB SACE
Connect the power supply
to a 220V power network
Set t he ON/OFF swit ch to
ON
Fit batteries like the ones
specified under the heading
"P ower supply"
Recharge the bat teries by
connecting t he unit to the
ext ernal power supply
Adjust as described under
the heading "Test unit
conf iguration"
Switc h on the unit and 10"
later select:
3. E NT ER
E NT ER
E NT ER
Select the correct language
with UP and DO WN.
Replace with the cable
supplied and repeat the
operation
Make s ure the c able
connectors are properly
inserted
Proceed as described under
the heading "S w updat ing
procedures"
Make s ure the P R010/ T unit
displays the message
"W ait ing for update" at the
start of the f ile t ransfer
procedure
Select the required sof tware
version and repeat the
update procedure
Select f ile type
PR010t_x.Hex
Use a spare c opy or
download t he updated
soft ware version from our
Internet site
cable
Replace with the cable
supplied and repeat the
operation
Make s ure the c able
connectors are properly
inserted
Fit the correct P R111
adapter
adapter is
Replace with the spare one
supplied
cable
is
Use the correct cable for
an
Emax
the circuit breaker in
question
Correctly insert the
connector, taking care to
check t he connector
polarity.
RH0025.002
L0876
20/22