  • Page 1 P100 Pedestal and F100 Frame I n s t a l l a t i o n M a n u a l 020-100734-02...
  • Page 3 P100 Pedestal and F100 Frame I n s t a l l a t i o n M a n u a l 020-100734-02...
  • Page 4 Christie's control such as maintenance of the product in proper working conditions. Performance specifications are based on information available at the time of printing. Christie makes no warranty of any kind with regard to this material, including, but not limited to, implied warranties of fitness for a particular purpose.
  • Page 5: Table Of Contents

    1.5 Contact Information........................1-2 2: Installation and Setup 2.1 Components ..........................2-1 2.1.1 For P100 Pedestals (Hardware Kit P/N: 000-102657-xx) ...........2-1 2.1.2 For F100 Frames (Hardware Kit P/N: 000-102673-xx) ............2-2 2.1.3 For LCD Video Wall Mounts and LCD Panels..............2-2 2.2 Kits Required ..........................2-2 2.3 Tools and Hardware Required .....................2-2...
  • Page 7: Using This Manual

    Setup is read in its entirety before installing this product. This manual provides technical information for assisting qualified service technicians in the installation of the P100 Pedestal and F100 Frame. Labels and Marking Observe and follow any warnings and instructions marked on the projector.
  • Page 8: Safety Warnings And Guidelines

    The P100 Pedestals, F100 Frames and LCD panels must be stacked onto a level surface. If stacked on a non- level or inclined surface, there is an increased risk that the structure (even when mounted in secured or free- standing external structures) could tip over and cause serious injury or damage.
  • Page 9: 2: Installation And Setup

    The following instructions outline how to install a display wall for the FHD551-X LCD panel, as a single or multi unit system – using the P100 pedestal and F100 frame. Additional important information relating to the display wall can be found in the ML10/MP10 40-65” LCD Video Wall Mount Instruction Sheet (P/N: 020- 100726-xx) and the LCD Panel FHD551-X User Manual (P/N: 020-100713-xx).
  • Page 10: For F100 Frames (Hardware Kit P/N: 000-102673-Xx)

    Service and Support Trained service technicians are available to diagnose and correct system-related problems. If you encounter any problems during the setup and installation of your system, contact the authorized dealer or Christie Partner from whom the system was purchased.
  • Page 11: Installation

    Section 2: Installation and Setup Installation 2.5.1 Assemble the Pedestals Once the pedestal platform is constructed it is essential an external support is constructed before adding the frames, video wall mounts and LCD Panels to prevent the display from tipping and causing serious injuries to those at the installation site. Depending on the size of the wall, assemble the platform beginning with the center pedestal, NOTICE! working outwards to the end of each row.
  • Page 12 Section 2: Installation and Setup 5. Loosely fasten the 2 pedestals together using 4 M6 hex nuts, 4 M6 hex head bolts, 8 flat washers and 4 lock washers. NOTES: 1) Keeping the hardware a little loose at this point will allow you to tweak the alignment between pedestals as more are added to the platform.
  • Page 13: Install Frames Onto Pedestals

    Section 2: Installation and Setup 2.5.2 Install Frames onto Pedestals Stacked LCD panels can tip over and cause injury or damage when not properly secured. The display wall must be supported during and after installation to a structurally sound surface, such as a permanent wall or an installer-approved free-standing external support structure.
  • Page 14: Adding Additional Rows Of F100 Frames

    Section 2: Installation and Setup 4. Using (4) M8 socket head cap screws and (4) flat washers (ɸ8.4), secure the 2 frames to one another using the 4 mounting points, as shown below. Hand tighten the hardware to allow small adjustments while the other frames are added to the row.
  • Page 15: Install Video Wall Mount Onto Frame

    Section 2: Installation and Setup 2.5.4 Install Video Wall Mount onto Frame For a detailed overview, refer to the ML10/MP10 40-65” LCD Video Wall Mount Instruction Sheet (P/N: 020-100726-xx) and the LCD Panel FHD551-X User Manual (P/N: 020-100713-xx). 2.5.5 Install FHD551-X LCD Panel For a detailed overview, refer to the ML10/MP10 40-65”...
  • Page 16: Connect Sources

    Section 2: Installation and Setup 2.5.7 Connect Sources A variety of external sources can be connected to the connection panel on the LCD panel. Properly routing the cables from 1 LCD panel to another in the display wall will keep them from becoming tangled. For a detailed overview, refer to the ML10/MP10 40-65”...
  • Page 17: A Mechanical Drawings

    A Mechanical Drawings Pedestal and Frame Installation Manual 020-100734-02 Rev. 1 (11-2011)
  • Page 19: Lcd Panel

    Appendix A: Mechanical Drawings A.1 LCD Panel DO NOT obstruct the air flow. 2.12 53.90 47.85 1215.30 M8 x 4 Mounting Holes, Length of screw engagement: 10mm (min), 15mm (max) Display Port HDMI 1 HDMI 2 DVI-D In PC Audio In VGA In DO NOT obstruct IR Extender...
  • Page 20: 2X2 Configuration Of Pedestal, Frame And Lcd Panel

    Appendix A: Mechanical Drawings A.2 2x2 Configuration of Pedestal, Frame and LCD Panel Minimum ‘Image to Image’ Gap Dimension 2x2 Configuration of Pedestal, Frame & LCD 5.70 Panel with Extended Mount for Service Pull Bracket Extension Hook on either side of panel to extend the display carriage 5.70 Pull strap to...
  • Page 21: Attaching Pedestal And Frame

    Appendix A: Mechanical Drawings A.3 Attaching Pedestal and Frame 16.44 13.78 General Notes: 417.66 350.00 1. Views shown here are for pedestal and frame assembly for landscape orientation. 2. Maximum adjustment possible using height adjustment knob is 25mm (1”). 3. Maximum range of adjustment on threaded foot along Y-axis is ±50mm (2”). 2.91 73.96 33.88...