Analog Output; Output For Q - Elis FLONEX FXx11x Series Control Instructions

Electromagnetic flowmeters
Table of Contents

Advertisement

ELIS PLZEŇ a. s.
Example:
A user has selected for display of instantaneous flow rate values the unit of m
100% flow rate value at 150 m
The above table gives the conversion coefficient between 1 m
The value to be set as the menu item 100% therefore is:
150 x 2.777778E-01 = 4.1666666E+01 (l/s).
5.1.4.3.

Analog output

(passive, current)
5.1.4.3.1. Output for Q−... Q+
Output
Q− .. Q+
Output
0 .. |Q|
Fixed current 4 . 20
ELIS PLZEŇ a. s., Lucni 425/15, 301 00 Plzeň, Czech Republic tel.:+420 377 517 711, fax:+420 377 517 722
Project design, installation and service manual
Electromagnetic flowmeters of the type series
FLONEX FXx11x and FLONET FH30xx
Meter control instructions
3
m
/s
3
m
/min
3
m
/h
3
m
/day
3
ft
/s
3
ft
/min
3
ft
/h
3
ft
/day
gal/s
gal/min
gal/h
gal/day
Mil Gal/day
bbl/s
bbl/min
bbl/h
bbl/day
ImpGal/s
ImpGal/min
ImpGal/h
ImpGal/day
3
/hour.
Flow rate for 20mA
ENTER
Flow rate for 4mA
Flow rate for 20mA
Flow rate for 4mA
1.000000E+03
1.666667E+01
2.777778E-01
1.157407E-02
2.831685E+01
4.719474E-01
7.865791E-03
3.277413E-04
3.785412E+00
6.309020E-02
1.051503E-03
4.381264E-05
4.381264E+01
1.589873E+02
2.649788E+00
4.416314E-02
1.840131E-03
4.546090E+00
7.576817E-02
1.262803E-03
5.261678E-05
3
/hour and litres per second 2.777778E-01.
ENTER
ENTER
ENTER
ENTER
Page 15 o
3
/hour and wishes to set the
Flow rate for 20mA
Output Q− .. Q+
l/s
+1.000000E+00
Flow rate for 4mA
Output Q− .. Q+
l/s
+1.000000E+00
Es 90 686 K
33
f