ELIS PLZEŇ a. s.
4. METER ENERGISING
4.1. Initial display status
Upon connecting the power supply to the meter, all its modules will undergo an initialisation procedure.
Following the display unit test, the basic screen format will appear on the display including information on:
Current volume flow rate measured by the meter
(if an error is indicated, its code will be shown next to the flow rate figure)
Aggregate flow volume passed through the meter in the positive direction
Aggregate flow rate passed through the meter in the negative direction
Shown in the top section of the display will be a bar graph relating the current volume flow rate to the
specified maximum flow rate.
4.2. Basic screen
4.3. Front panel and control buttons
4.3.1. Display unit
The flowmeter includes a colour OLED display of 128x64 pixels providing visual information to the user on
all measured quantities, meter parameter settings and important operational information. The display
control is facilitated by four optical buttons (optical reflex sensors).
4.3.2. Control button functions
Button positions with respect to the display unit
1
4
1
ELIS PLZEŇ a. s., Lucni 425/15, 301 00 Plzeň, Czech Republic tel.:+420 377 517 711, fax:+420 377 517 722
Project design, installation and service manual
Electromagnetic flowmeters of the type series
FLONEX FXx11x and FLONET FH30xx
Meter control instructions
▲
►
⃝
⃝
■■■■■■■■■■■■■■■■■■■
1,025
m3/h
45,34
m3
- 25,1
⃝
⃝
ENTER
ESC
2
3
Es 90 686 K
Page 5 o
33
f