Gp 23 Motor Control - Xerox FaxCentre F110 Service Manual

Hide thumbs Also See for FaxCentre F110:
Table of Contents

Advertisement

GP 23 Motor Control

Connection
The digicolor2 drives one stepping motor for the printer module. This motor is controlled by cur-
rent. The motor is controlled using the motor control block
The driver for the printer motor is the L9219 from STM (SO24 package) with 5V power supply. The
motor is supplied from the 24V.
Digicolor2
PB_DATA3
PB_DATA2
PB_DATA1
PB_DATA0
During the reset mode (power on) the signal AE1* is configured as input direction. A pull-up on
the buffer input OE* forces the output of the buffer to high-impedance state. External pull-up I01,
I11, I02, and I12 protects the motor.
After reset the motor buffer must be forced to the value 00h.The signal AE1* is controlled as output
"0" to access motor and "1" for motor stand-by.
The maximum peak current is set using a voltage divider on the input Vref. The PWM frequency
is set by the two RC filters R260, C253 and R261, C254. The current in each phase is sensed by
two 1ohm resistor in parallel: R266, R267.
In this application, the maximum current is set to 600mA.
FaxCentre F110
Buffer
PMEN2*
PMEN1*
PMOT2
PMOT1
Figure 1
12/04
General Procedures / Information
L6219
PMOTA0
PMOTB0
PMOTA0#
PMOTB0#
Paper
motor
6-57