Shipped Unit Dimensions - Trane Tracer CH535 Manual

Chiller controller
Hide thumbs Also See for Tracer CH535:
Table of Contents

Advertisement

Alarms
Table 4 – Status, Warning and Alarm messages
Message
1
No Alarm
FWD
Power supply
2
Alarm Water Pump1
Capacities
3
Alarm Water Pump2
Cooling capacity on water (1)
Heating capacity on water (2)
4
User Ckt1 Stop
Fan motor
Fan power input (3)
5
User Ckt2 Stop
Current amps (3)
Start-up amps
6
Ext. Ckt1 Stop
Air flow
minimum
7
Ext. Ckt2 Stop
nominal
8
Rem. Ckt1 Stop
maximum
Main coil
9
Rem. Ckt2 Stop
Water entering/leaving connections
10
Clock Unit Stop
Electric heater (accessory for blower only)
Electric power supply
11
Operator Stop
Heating capacity
12
Phase Fault
Hot water coil (accessory for blower only)
Heating capacity (4)
G2 filter (filter box accessory)
13
Warning Ckt1 LP Limit
Quantity
Dimensions ( LxWxth)
G4 filter (filter box accessory)
14
Warning Ckt2 LP Limit
Quantity
Dimensions ( LxWxth)
Condensate pump (accessory)
15
Warning Ckt1 HW Limit
Water flow - lift height
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
16
Warning Ckt2 HW Limit
Sound pressure level (5)
Sound power level (5)
Unit dimensions
17
Warning Ckt1 HP Limit
Width x Depth
Height

Shipped unit dimensions

18
Warning Ckt2 HP Limit
Width x Depth
Height
Weight
19
Warning Ckt1 HT Limit
Colour
Recommended fuse size
Unit alone (aM/gI)
20
Warning Ckt2 HT Limit
Unit with electric heater (gI)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
21
Warning Ckt1 CIPD Limit
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
22
Warning Ckt2 CIPD Limit
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Warning Low SuperHeat
Accessories - Hot water coil:
23
ckt1
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Warning Low SuperHeat
24
ckt2
Alarm Outside Air Temp
25
Cooling: Too Low
Heating: Out of Range
26
Ckt1 Defrost
4
10
Technical Data
Reset
Unit Status
Type
-
Unit On
08
(V/Ph/Hz)
Manual
Unit On
Manual
Unit On
(kW)
5,2
(kW)
6,3
-
Circuit 1 Off
(type)
(kW)
0,23
-
Circuit 2 Off
(A)
1,1
(A)
3,2
-
Circuit 1 Off
(m
/h)
-
Circuit 2 Off
490
3
(m
/h)
820
3
-
Circuit 1 Off
(m
/h)
980
3
-
Circuit 2 Off
(type)
(Dia)
3/4"
-
Unit Off
(V/Ph/Hz)
230/1/50
-
Unit Off
(kW)
2/4
Auto
Unit Off
(kW)
6,3
Auto
Circuit 1 Limit
2
(mm)
386x221x8
Auto
Circuit 2 Limit
-
(mm)
-
(type)
Auto
Circuit 1 Limit
(l/h - mm)
Auto
Circuit 2 Limit
(dB(A))
36/40/43
(dB(A))
46/50/53
Auto
Circuit 1 Limit
(mm)
890 x 600
(mm)
250
Auto
Circuit 2 Limit
(mm)
933 x 644
(mm)
260
(kg)
32
Auto
Circuit 1 Limit
(A)
8/16
Auto
Circuit 2 Limit
(A)
16 (2kW),25 (4kW)
Auto
Circuit 1 Limit
Auto
Circuit 2 Limit
Auto
Circuit 1 Off
Auto
Circuit 2 Off
Auto
Unit Off
-
Unit On
Description
See unit status on Main display
12
20
230/1/50
Defective water pump 1
Defective water pump 2
8,3
15
11,9
18,9
Circuit 1 Disable by Settings (via keyboard)
2 x direct drive centrifugal
0,46
0,65
Circuit 2 Disable by Settings (via keyboard)
2,2
3,1
5,5
9,3
Circuit 1 Off by Digital Input (Duplex units)
Circuit 2 Off by Digital Input (Duplex units)
980
1400
1650
2300
Circuit 1 Disable by Supervision
1970
2600
Circuit 2 Disable by Supervision
ISO R7 rotating female
3/4"
1 1/2"
Unit Off by Program (Hourly, Weekly)
230/1/50 or 400/3/50
400/3/50
Unit Off by Operator (via keyboard)
8
10
Phase Loss or Phase Reversal
12
17,4
Suction pressure on circuit 1 is below the setpoint
(1.5barG).
2
2
486x271x8
586x321x8
Suction pressure on circuit 2 is below the setpoint
(1.5barG).
2
2
486x264x48
586x314x48
Leaving water temperature is above the setpoint
Centrifugal
(Default value: 25°C).
24 - 500
Leaving water temperature is above the setpoint
38/41/44
46/50/53
(Default value: 25°C).
48/51/54
56/60/63
Discharge pressure on circuit 1 is above the
1090 x 710
1290 x 820
setpoint (Default value: 43.1barG).
300
350
Discharge pressure on circuit 2 is above the
1133 x 754
1333 x 864
setpoint (Default value: 43.1barG).
310
360
Discharge temperature on circuit 1 is above the
46
61
galvanised steel
setpoint (Default value: 128°C).
Discharge temperature on circuit 2 is above the
8/16
8/16
40 (230V),3*16 (400V)
3*20
setpoint (Default value: 128°C).
Compressor Involute Pressure Differential on
circuit 1 is above 22.2barG or above 18.6barG
during 25min.
Compressor Involute Pressure Differential on
circuit 2 is above 22.2barG or above 18.6barG
during 25min.
Super Heat on circuit 1 is below low limit (2°C)
Super Heat on circuit 2 is below low limit (2°C)
Ambient temperature is out of range for unit
operation:
Cooling mode: below -10°C (default value)
Heating mode: below -15°C (default value) or
above 29°C.
Defrost on Circuit 1
30
45
18,8
30,1
20,9
38,2
1,04
1,51
4,7
5,5
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
12
12
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
450
650
1333 x 1008
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25
UNT-PRC002-GB
CG-SVU007D-GB