Download Print this page

TE Connectivity D369 Series Instruction Sheet

Panel-mount receptacle connectors

Advertisement

Quick Links

For an overview of D369 series connectors,
For receptacle part numbers, refer to the customer drawings given in Figure 1.
Size 3 Receptacle
D612015-3-ENV
NOTE
Dimensions in this instruction sheet are in metric units [with U.S. customary units in brackets]. Figures are not drawn to scale.
1. ASSEMBLY
1. Crimp the contacts following the guidelines given in SAE AS39029, "General Specification for
Contacts and Electrical Connectors", then insert the contacts into the receptacle contact cavities.
2. Refer to Figure 2 and ensure that the panel gasket is compatible with the receptacle size and panel
thickness. The number of panel gasket identifiers corresponds to the panel thickness. If it is not
compatible:
a. From the mating face of the receptacle, pull the panel gasket from the receptacle.
b. Choose the appropriate panel gasket. Refer to Figure 2.
c. With the back (side without pads) of the panel gasket facing the mating face of the receptacle,
align the panel gasket identifiers with the receptacle panel latch (on top or bottom), then slide the
panel gasket onto the receptacle and hook the back over the receptacle flange. See Figure 2.
Receptacle Panel
Latch (Top Shown)
Panel Gasket
Identifiers (2 Shown)
Panel Gasket
Pad (4 Places)
RECEPTACLE SIZE
3
6
9
© 2016 TE Connectivity family of companies
All Rights Reserved
*Trademark
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners.
D369 Series Panel-Mount
Receptacle Connectors
view our video
Size 6 Receptacle
D612015-6-ENV
Figure 1
Receptacle
Flange
Mating Face
of Receptacle
PANEL THICKNESS (mm [in.]) ±0.10 [±.004]
1.27 [.05]
PANEL GASKET 612154-(Suffix Number) Number of Receptacle Panel Gasket Identifiers
2
3-A
6-A
9-A
Figure 2
PRODUCT INFORMATION 1-800-522-6752
at www.te.com.
Size 9 Receptacle
D612015-9-ENV
Panel Gasket Installed on Receptacle
Panel Gasket Identifiers
Aligned with Top
1.60 [.06]
3
3-B
6-B
9-B
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com.
Instruction Sheet
408-32194
09 MAR 16
Rev A
Panel Gasket Identifiers
Aligned with Bottom
Mating Latch (Ref)
2.03 [.08]
4
3-C
6-C
9-C
1 of 3

Advertisement

loading

Summary of Contents for TE Connectivity D369 Series

  • Page 1 1 of 3 For latest revision and Regional Customer Service, All Rights Reserved *Trademark visit our website at www.te.com. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners.
  • Page 2 408-32194 3. Prepare the panel with a cutout meeting the dimensions given in Figure 3. R 0.60 mm [.023 in.] Max Note: Not to Scale PANEL THICKNESS (mm [in.]) ±0.10 [±.004] PANEL CUTOUT DIMENSION (mm [in.]) RECEPTACLE Number of Receptacle Panel Gasket Identifiers MINIMUM PITCH (Centerline) B (Height) SIZE...
  • Page 3 408-32194 2. DISASSEMBLY 1. Push the release button of the plug, then pull the plug straight from the receptacle. 2. From the front of the panel, align the opening of removal tool (refer to drawing D612184-ENV for part numbers) with the mating face of the receptacle according to the orientation markings on the side of the tool (arrows pointing toward front of panel), and slide it over the receptacle until it bottoms on the panel.

This manual is also suitable for:

D612015-3-envD612015-6-envD612015-9-env