MAINTENANCE

10.
MAINTENANCE
ATTENTION
Any cleaning, inspection, control, routine and extraordinary maintenance must be performed by experienced, authorised personnel and qualified to perform
the above tasks. These tasks must be performed to perfection as prescribed by M.D. 37/2008.
During the execution of
- Risks of electric discharges;
-
Risk of injuries due to the presence of rotating parts;
-
Risk of injuries due to the presence of sharp edges and heavy weights;
-
Risks of injuries due to the presence of components containing high pressure gas;
-
Risks of injuries due to high or low temperature components.
-
Noise-related risks of the machine functioning;
-
Risks related to the presence of harmful substances in hydronic circuits.
These tasks must be performed using the appropriate personal protective equipment, see figure below
Maintenance operations are essential to maintain the refrigerant unit efficient, from a purely functional point of view and with regard to energy and safety.
In the absence of specific regulations regarding HFO refrigerants, the manufacturer prescribes the application of and compliance with that indicated in the:
- Regulation (EC) No.842/2006- art.3 concerning the "leakage containment"
- Regulation (EC) No.1516/2007 concerning the "standard leakage checking requirements" and related national laws implementing the above European
regulations.
ATTENTION
For the unit, the user must provide a system booklet which he must ensure, or its designee authorised to service the machine, will contain all required
records in order to have a historical documentation of the unit functioning. The absence of records in the booklet may count as evidence of lack of mainte-
nance..
PRECAUTIONS TO BE OBSERVED DURING MAINTENANCE
ATTENTION
Maintenance operations can only be performed by authorised technicians
PRECAUTIONS AGAINST RESIDUAL RISKS
MECHANICAL RISKS
- Before opening a machine panel, ascertain whether it is or not firmly connected to it by hinges;
- In case a piece is disassembled, make sure it is correctly reassembled before restarting the unit;
- Louvers of the heat exchangers, edges of the components and panels, screws can generate cuts;
- Do not remove the protections from mobile elements while the unit is running;
- Make sure that the protections of mobile elements are correctly in place before restarting the unit;
- It is not permitted to walk or place other bodies on the machine;
- Fans, motors and belt drives may be in motion, always wait for them to stop and take appropriate precautions to prevent their activation before accessing
them;
-
Isolate the unit from the mains by means of the external isolator provided for the insertion of padlocks (up to 3) for blocking in "open" position.
-
Place a sign reading "Do not turn on - maintenance in progress" on the open isolator
-
Equip yourself with the appropriate personal protective equipment (helmet, insulated gloves, protective goggles, accident-prevention shoes, etc.)
-
Equip yourself with tools in good condition and make sure to have fully understood the instructions before using them
-
For outdoor units, do not perform interventions in dangerous weather conditions such as rain, snow, fog, etc.
-
The cooling circuit contains under pressure refrigerant gas: any operation must be performed by competent personnel in possession of the authorisations
and qualifications required by current laws
ATTENTION
it is forbidden to LOAD the cooling circuit with a refrigerant gas different from that indicated. Using different refrigerant gas can
severely damage the unit
-
never disperse the fluid contained in the cooling circuit in the environment
-
never keep the cooling circuit open, because the oil absorbs humidity and degrades
-
during venting protect yourself against any leakage of fluids at dangerous temperatures and/or pressures
-
always use appropriate equipment (extractor, antistatic bracelet, etc.) when replacing electronic boards
-
if replacing a motor, compressor, evaporator, condensing coils or any other heavy element, make sure that the lifting devices are compatible with the wei-
ght to be handled
-
in air units with independent compressor compartment, do not access the fan compartment without having first disconnected the machine through the
isolator on the board and having placed a sign reading "Do not turn on - maintenance in progress"
-
contact the company if changes must be made to the refrigerant, hydraulic or electric diagram of the unit, as well as its control logic
PREVENTION OF CHEMICAL / FIRE / ENVIRONMENTAL RISKS
-
Any intervention on the machine must be performed with "NO SMOKING";
-
The water circuit may contain harmful substances. Prevent the contents coming into contact with skin, eyes and clothing. Use the prescribed personal
protective equipment. (chemical risk);
-
If there is a need to perform a braze-welding, so with the use of special torch with naked flame, the same flame must only be activated if in the absence of