Page 3
Thank you again. AERMEC S.p.A AERMEC S.p.A. reserves the right at any moment to make any modifications considered necessary to improve our products and is not obliged to add these modifications to machines that have already been fabricated, delivered or are under construction.
SUMMARY General warnings ............6 Product identifi cation..........6 Description and choice of unit ........7 Confi gurator ..............8 Description of the components .........9 5.1. Cooling circuit ..............9 5.2. Frame and fans ............9 5.3. Hydraulic circuit ............9 5.4. Control and safety components ......10 5.5.
Page 5
AERMEC S.p.A. I-37040 Bevilacqua (VR) Italia – Via Roma, 996 Tel. (+39) 0442 633111 Telefax 0442 93730 – (+39) 0442 93566 www.aermec.com - info@aermec.com ANLH SERIAL NUMBER CE DECLARATION OF CONFORMITY We, the undersigned, hereby declare under our own responsibility that the...
PRESERVATION OF THE cover the costs for ladders, scaf- DOCUMENTATION folding, or other elevation systems AERMEC ANLs are constructed ac- The instructions along with all the that may become necessary for cording to the recognised techni- related documentation must be gi-...
DESCRIPTION AND CHOICE OF They are available in the following ce that the oil in the sump compressor UNIT versions: is heated for at least 8 hours using the electrical resistances. The sump resistan- − HEAT PUMP ANL H ANL R410A coolers and air cooled ce is powered automatically when the Winter to summer switch-over heat pumps have been designed...
CONFIGURATOR 1,2,3 4,5,6 ° ° ° ° FIELD CODE 1, 2 ,3 4, 5, 6 SIZE 100 -150 MODEL Heat Pump VERSION with storage tank and pump HEAT RECOVERY without heat recovery units ° COILS in aluminium ° FIELD OF USE temperature of water produced up to 4 °C / 39°F °...
Examples of hydraulic circuits DESCRIPTION OF THE COMPO- the diagram shown here are an NENTS example exchanger, withholding excess liquid 5.1. COOLING CIRCUIT during winter functioning. Compressor 5.2. FRAME AND FANS High efficient scroll type on anti-vibra- tion mounts, activated by a 2-pole electric motor with internal circuit Ventilation unit breaker protection.
b. Compressor ON/OFF 5.4. CONTROL AND SAFETY COMPO- for pressing line and coil c. Functioning mode (hot/cold) NENTS − External air temperature probe WITH d. Alarm active High pressure pressure switch (HP) DCPX ACCESSORY Probes, transducers and parameters display 5.6. ELECTRONIC MODU CONTROL With fixed calibration, placed on high a.
OPERATING LIMITS The units, in standard configura- For functioning limits, please refer AERMEC technical-sales dept. tion, are not suitable for installation to the diagrams below, valid for If it is installed in a particularly in salty environments. The maxi- ∆t = 5 °C (40 °F).
ETHYLENE GLYCOL FcGDpF (a) 2.20 SOLUTIONS FcGDpF (b) 2. 1 0 2.00 FcGDpF (c) 1.90 − The correction factors of cooling FcGDpF (d) 1.80 power and input power take into 1.70 account the presence of glycol 1.60 FcGDpF (e) and diverse evaporation tempera- 1.50 tures.
11.2. STATIC PRESSURES USEFUL TO THE SYSTEM The static pressures stated here are − The static pressures are calcu- − WITH PRESENCE OF GLYCOL for at net of the pressure drops of the lated in cooling mode. static pressures useful to system heat exchangers, filter, storage PLEASE CONTACT COMPANY.
STORAGE TANK ANL 100-150 Hydraulic height 30/98 25/82 20/66 15/49 ≥12.25/40 The following tables highlight prin- Calibration of expansion vessel bar/psi 3.2/46 2.8/41 2.3/33 1.8/15 1.5/22 ciple characteristics for hydraulic l (1) Water content reference values circuit components, whilst the graph l (2) Water content reference values on the following page shows relative...
SOUND DATA Sound power Total sound levels Octave band [Hz] Aermec determines sound power values in Pressure. 1000 2000 4000 8000 Pow. agreement with the 9614 Standard, in com- dB(A) dB(A) Sound power for centre of band [dB] frequency dB(A) pliance with that requested by Eurovent 10 m/33 ft.
Page 19
14.2.1. ANL 100-150 HA VERS. WEIGHTS BARYCENTRES lbs. ANL100H ANL150H 1800 / 71 in. 750 / 30 in. 1750 / 69 in. Ø 34 IN1”¼ OUT 1”¼ (5.4 in) 80 / 3 in. 1590 / 63 in. 80 / 3 in. Mod.
FOR THE INSTALLER RECEIVING THE PRODUCT AND 15.1.1. SELECTION AND PLACE OF INSTALLATION INSTALLATION 15.1. RECEIVING THE PRODUCT AND Before installing the HANDLING unit, decide withthe customer the position in The unit is sent from the factory wrap- which it will be placed, ped in estincoil placed on a pallet.
FEAUTERS WATER Alkalinity M less than 50 ppm Electric conductivity Total hardness less than 50 ppm less than 200 mV/cm (25°C)/(77°F) Chloride ions less than 50 ppm Sulphur ions none Sulphuric acid ions less than 50 ppm Ammonia ions none Total iron less than 0,3 ppm Silicone ions...
Page 24
Tel. (+39) 0442 633111 The technical data in the following Telefax 0442 93730–(+39) 0442 93566 documentation are not binding. www.aermec.com - info@aermec.com Aermec reserves the right to make all the modifications considered necessary for improving the product at any time.