Operating Manual
VacuMaster

1.5 Intended Use

Danger

1.6 Emissions

1.7 Special Hazards

1.8 Workplaces

1.9 Instructions for the
Operator
1.10
Equipment for
Personal Protection
1.11
Behaviour in
Emergencies
1.12
Checking the
Safety Devices
BA 30.30.01.00197
Chapter 1
Safety
Lifting devices of the V
ACU
flat parts, workpieces, plates and boards of various materials near the ground.
The surface of the items to be lifted must not be porous.
The maximum lifting capacity must not be exceeded.
The lifting device may be used only suspended from its suspension shackle
or bolt.
Transport of persons and animals with the load or the lifting device itself is
forbidden!
Unauthorised modification of the lifting device is forbidden for safety
reasons!
The operating, maintenance and service instructions in this manual must
be observed.
The equivalent continuous sound pressure level of the device is
less than 70 dB(A).
Since the load is held by a vacuum, it will fall off as soon as this vacuum is lost.
This can happen if the vacuum generator fails. In such cases, an integrated
vacuum reservoir maintains the vacuum for a short period (depending on the
quality of the seal between the suction pads and surface of the workpiece).
If the power fails, lower the load immediately if this is possible. If this is not
possible, immediately leave the dangerous area near the load.
The device generates a very strong suction which can draw in hair and
clothing. Do not look into the suction opening when the device is switched on.
Parts of body can be sucked in.
The workplace of the operator is in front of the control handle. Stand so that
you can constantly observe the vacuum gauge.
As an operator of the lifting device, you must be trained before you start to use
the device. You must have read and understood the operating instructions and
especially the chapter "Safety".
Ensure that only authorised persons use the device. You are responsible for
others in the operating range of the equipment.
Local safety requirements are fully applicable. The safety instructions in this
document complement these local regulations and do not supersede them.
When operating the device always wear:
safety shoes (with steel toecaps),
tough gloves.
An emergency situation exists when
power suddenly fails (device switches off),
the vacuum pressure drops below -0.6 bar to the red section on the scale
of the vacuum gauge.
Lower the load immediately if possible. If this is not possible, immediately leave
the dangerous area near the load, since it will be dropped from the device.
The lifting device is equipped with following safety devices:
vacuum gauge with red danger zone
warning device, audible
Check these devices at the beginning of each shift (when operating in shifts) or
once a week (when operating continually).
Status 03.2013 / Index 00
J. Schmalz GmbH
Aacher Straße 29
D - 72293 Glatten
Tel +49 +7443 / 2403 - 0
Fax +49 +7443 / 2403 - 259
http://www.schmalz.de
e-mail: schmalz@schmalz.de
M
series are designed for lifting and moving
ASTER
Page 5 / 18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vacumaster 2000

Table of Contents