Gaymar Thermacare TC3146 Operating Manual

Convective warming system

Advertisement

Quick Links

Thermacare TC3146
Convective Warming System
Système de réchauffement par convection
Aparato de calentamiento convectivo
Operating Manual
Manuel d'utilisation
Manual del usuario
P/N 12536000 Rev A 12/07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Thermacare TC3146 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gaymar Thermacare TC3146

  • Page 1 Thermacare TC3146 Convective Warming System Système de réchauffement par convection Aparato de calentamiento convectivo Operating Manual Manuel d'utilisation Manual del usuario P/N 12536000 Rev A 12/07...
  • Page 2 Failure to do so within 15 days may result in HIGH (110°F, 43°C) loss of claim. Contact your local dealer or contact Gaymar's Technical Service Department (see back cover REMOVE FROM USE for phone numbers) for assistance.
  • Page 3: Table Of Contents

    Table of Contents Table of Contents Section Description Page Safety Precautions ..............2 Introduction ................3 Operator Control Panel ............4 Operating Instructions ............5 Routine Maintenance .............. 6 Troubleshooting ..............7 Quilts / Training / Warranty / Returns ........7 Specifications ................
  • Page 4: Safety Precautions

    Section 1 - Safety Precautions 1.0 Safety Precautions Review the following SAFETY PRECAUTIONS If vital signs become unstable, notify the prior to using the Power Unit. These SAFETY attending physician immediately. PRECAUTIONS appear within this manual, the Power Unit label, or the Quilt Instructions for Use. •...
  • Page 5: Introduction

    2.0 Introduction Please read the precautions found in section 1.0 and all operating instructions before attempting to use the Thermacare TC3146 Convective Warming System. In addition, we recommend you request in-service training from your local dealer. 2.1 Convective Warming System The Convective Warming System (fig.
  • Page 6: Operator Control Panel

    Section 3 - Operator Control Panel ➁ ➂ Figure 4 - Operator Control Panel 3.3 REMOVE FROM USE Indicator ➂ The REMOVE FROM USE indicator will light: • if a patient limit thermostat or heater overtemp thermostat has tripped, or • if the HEPA filter has been installed incorrectly or is missing. The heating element and blower will automatically turn off when either of these conditions occur.
  • Page 7: Operating Instructions

    Section 4 - Operating Instructions Insert the end of the hose into the Quilt IMPORTANT opening (fig. 5). Secure the hose tightly. Read and understand these instructions Plug the Power Unit into a “Hospital Grade” and the precautions on the inside front outlet.
  • Page 8: Routine Maintenance

    Section 4 - Operating Instructions (cont’d) Section 5 - Routine Maintenance 4.10 Shutdown Procedure NOTE: • The air temperature surrounding the patient will When therapy has been completed, turn the vary at each setting, depending upon room air unit off and disconnect the hose from the Quilt. temperature and the quality of the insulating Discard the Quilt.
  • Page 9: Troubleshooting

    Have qualified service personnel check for a clogged or dirty HEPA filter. 7.4 Limited Warranty The Thermacare TC3146 Power Unit is warranted 6.2 REMOVE FROM USE Indicator is Lit free of defects in material and workmanship This indicates that the heater and blower have...
  • Page 10: Specifications

    Section 8 - Specifications 8.0 Specifications 8.3 Temperature Settings The air temperatures are identified on the operator 8.1 Physical control panel and indicate the average air Dimensions "H x 10 "W x 10 "D temperature at the hose end using a Quilt. 42 cm x 28 cm x 27 cm NOTE: The air temperature around the Weight...
  • Page 11 GAYMAR INDUSTRIES, INC. 10 Centre Drive Orchard Park, NY 14127-2295 USA Phone: 1 800 828-7341 (716) 662-2551 Fax: 1 800 993-7890 (716) 662-0748 www.gaymar.com...