1-11. Cleaning when the Heads are Clogged

1-12. Tracking Adjustment and Audio Meter Brightness Adjustment

1-11. Cleaning when the Heads are
Clogged
For details on how to clean the video head, refer to Section
"5-2-3. Cleaning the Tape Running Surface of the Upper
Drum and Video Heads".
The video heads should be cleaned periodically to avoid
head clogging.
1-24
1-12. Tracking Adjustment and Audio
Meter Brightness Adjustment

1-12-1. Tracking Adjustment

To adjust the tracking, perform the following procedure.
1. Perform the following operations in the setup menu.
(Refer to Section 3-1.)
PAGE : <TRACKING>
ITEM : AUTO TR → OFF
2. Remove the screw and open the L SUB cover.
3. Insert the screwdriver tip into the hole for tracking
adjustment and adjust the tracking.
L SUB cover
Screwdriver
Hole for LCD contrast adjustment

1-12-2. Audio Meter Brightness Adjustment

To adjust the audio meter brightness, perform the follow-
ing procedure.
1. Remove the screw and open the L SUB cover.
2. Insert the screwdriver tip into the hole for LCD
contrast and adjust the LCD brightness.