7.2 Changing the crimping length

The crimping length is changed using a rotary dial.
Changing the crimping length
Changing the rotary dial
Follow the steps mentioned above to remove the stripping blade and crimping jaws (see
Page 22)
Insert the rotary dial (1) at the desired crimping length using a screwdriver
The selected value is shown via the red marker (2).
Re-attach individual parts
PA29440A01_00 ENG
OPERATION MANUAL
Changing the stripping blade and crimping jaws
CP-991: No change.
CP-992: The crimping jaws and stripping blade
must be altered during a cross section change.
The steps for removing the cord-centering funnels
are mentioned above
Take out both of the stripping blades (1 + 2)
Slide the cassette (3) upwards
Take out both of the crimping jaws (4 + 5)
Attach in the reverse order
NOTE: Check for correct lock-in position.
Changing the separation plates
CP-991: The separation plates must be changed
during a 0.5...1.5 ↔ 2.5 cross section change.
CP-992: The separation plate must be changed
during a 4 ↔ 6 ↔ 10 cross section change.
Unscrew the separation plate (1) using the hexagonal
wrench and remove (2)
Remove the separation plate from the retrofit kit with
the desired cross section and attach in place of the
previous separation plate
Page: 22 of 26