Automatic wire stripping and ferrule crimping press
Table of Contents

Advertisement

Available languages

Available languages

© Panduit Corp. 2018
1
PA29440A01_00 ENG
OPERATION MANUAL
Connecting CP-991
CP-991: 4.5 bar ... 6 bar of filtered air
CP-992: 5 bar ... 6 bar of filtered air
Connect compressed air connection (1) to the
compressed air supply
Check air pressure at manometer (2):
Operating pressure 5 bar, at least 4.5 bar (CP-991)
Operating pressure 5.5 bar, at least 5 bar (CP-992)
Set air pressure, if necessary. Pull the air pressure
regulator
(3) upwards, set the air pressure by turning (4) to the
right (+) or left (-) and then press the regulator (5)
downwards
Connect the main plug to the CP-991 main
connection and the shock-proof plug to the main
socket
Stripping conductors
A Stripping
Press the "Strip" button.
B Stripping and crimping
Press the "Strip and crimp" button. Set the speed
of the feeder bowl.
Wait until the ferrule is visible at the separation
plate (1).
A and B
Insert the conductor straight into the insertion funnel
until it stops. As soon as the CP-991 starts, hold the
conductor with slight tension
The conductor is automatically stripped
When the CP-991 has stopped, pull the conductor
out
In the event of a malfunction or improper stripping,
see Page 23.
Shutting down
If necessary, read the counter and reset to zero
Switch off the CP-991 with the main switch