Download Print this page

Kenwood NX-3400 Service Manual page 55

800/900mhz digital transceiver

Advertisement

Item
Condition
<PC>: PC tuning mode
<Panel>: Panel tuning mode
5.Squelch
<PC>
Tight
1) Adj item: [Squelch Tight (Analog
[Analog Wide
Wide 5k)]
5k]
2) SSG output: 12dB SINAD level
+6dB (MOD: 1kHz/±3.0kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
<Panel>
1) Adj item: [Aw SQLT]
2) SSG output: *Same as above
3) Adj points: *Same as above
[Analog Wide
<PC>
4k]
1) Adj item: [Squelch Tight (Analog
Wide 4k)]
2) SSG output: 12dB SINAD level
+6dB (MOD: 1kHz/±2.4kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
<Panel>
1) Adj item: [As SQLT]
2) SSG output: *Same as above
3) Adj points: *Same as above
[Analog
<PC>
Narrow]
1) Adj item: [Squelch Tight (Analog
Narrow)]
2) SSG output: 12dB SINAD level
+6dB (MOD: 1kHz/±1.5kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
<Panel>
1) Adj item: [An SQLT]
2) SSG output: *Same as above
3) Adj points: *Same as above
6. Low RSSI
<PC>
1) Adj item: [Low RSSI (Analog
Narrow)]
2) SSG output: -118dBm (0.28V)
(MOD: 1kHz/±1.5kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
<Panel>
1) Adj item: [An LRSSI]
2) SSG output: *Same as above
3) Adj points: *Same as above
Measurement
Unit Parts
SSG
[+], [-]
Distortion
meter
Oscilloscope
[], []
SSG
[+], [-]
Distortion
meter
Oscilloscope
[], []
SSG
[+], [-]
Distortion
meter
Oscilloscope
[], []
SSG
[+], [-]
Distortion
meter
Oscilloscope
[], []
Adjustment
Method
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for <PC>, or press [
button for < Panel>, to store the
adjustment value.
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for <PC>, or press [
button for < Panel>, to store the
adjustment value.
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for <PC>, or press [
button for < Panel>, to store the
adjustment value.
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for <PC>, or press [
button for < Panel>, to store the
adjustment value.
(No.RA070<Rev.001>)1-55