Download Print this page

Kenwood NX-3400 Service Manual page 54

800/900mhz digital transceiver

Advertisement

Item
Condition
<PC>: PC tuning mode
<Panel>: Panel tuning mode
[Analog
<PC>
Narrow]
1) Adj item: [Squelch Open (Analog
Narrow)]
2) SSG output: 12dB SINAD level
-3dB (MOD: 1kHz/±1.5kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
<Panel>
1) Adj item: [An SQL]
2) SSG output: *Same as above
3) Adj points: *Same as above
[NXDN
<PC>
Narrow]
1) Adj item: [Squelch Open (NXDN
Narrow)]
2) SSG Output: 12dB SINAD level
at Analog Narrow -5dB
(MOD: 400Hz/±1.5kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
<Panel>
1) Adj item: [Nn SQL]
2) SSG output: *Same as above
3) Adj points: *Same as above
[NXDN Very
<PC>
Narrow]
1) Adj item: [Squelch Open (NXDN
Very Narrow)]
2) SSG Output: 12dB SINAD level
at Analog Narrow -2dB
(MOD: 400Hz/±1.5kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
<Panel>
1) Adj item: [Nv SQL]
2) SSG output: *Same as above
3) Adj points: *Same as above
[DMR]
<PC>
1) Adj item: [Squelch Open (DMR)]
2) SSG Output: 12dB SINAD level
at Analog Narrow -4dB
(MOD: 400Hz/±1.8kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
<Panel>
1) Adj item: [D SQL]
2) SSG output: *Same as above
3) Adj points: *Same as above
1-54 (No.RA070<Rev.001>)
Measurement
Unit Parts
[+], [-]
[], []
SSG
[+], [-]
Distortion
meter
Oscilloscope
[], []
SSG
[+], [-]
Distortion
meter
Oscilloscope
[], []
SSG
[+], [-]
Distortion
meter
Oscilloscope
[], []
Adjustment
Method
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for <PC>, or press [
button for < Panel>, to store the
adjustment value.
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for <PC>, or press [
button for < Panel>, to store the
adjustment value.
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for <PC>, or press [
button for < Panel>, to store the
adjustment value.
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for <PC>, or press [
button for < Panel>, to store the
adjustment value.
Specifications
/Remarks
]
]
]
]

Hide quick links:

Advertisement

loading