Download Print this page

Kenwood NX-3400 Service Manual page 32

800/900mhz digital transceiver

Advertisement

4.3
Panel Tuning Mode
4.3.1 Transceiver tuning (To enter tuning mode)
To enter tuning mode, press the [
is in test mode. Use the [
tuning modes, and the [  ]/[  ] button to adjust tuning
requirements (1 to 4096 appears on the LCD).
Use the [
] button to select the adjustment item through tuning
modes. Use the [
] button to adjust 5, 6 or 10 reference level
adjustments, and use the [  ] button to switch between Wide 5k/
Wide 4k/Narrow.
• LCD display in panel tuning mode
CV voltage, AD value, etc
2.6
Sub LCD display
800M TX L
An
Main LCD display
Adjustment point
800M TX L
800M TX C
An : Analog narrow mode
800M TX H
Aw : Analog wide 5k mode
800M RX/TA L
As : Analog wide 4k mode
800M RX/TA C
Nn : NXDN narrow mode
800M RX/TA H
Nv : NXDN very narrow mode
900M TX L
D : DMR mode
900M TX H
900M RX/TA L
900M RX/TA H
4.3.3 5, 6 or 10 reference level adjustments frequency
5 reference level adjustment
IQ Phase / RSSI Reference 1 DSP (Receive) / RSSI Reference 2 RF IC (Receive) / RSSI Reference 3 DSP(Standby) / RSSI
Reference 4 RF IC (Standby) / Squelch Open / Squelch Tight / Low RSSI / High RSSI
<5 points>
Tuning No.
Name
1
800MHz TX Low
2
800MHz TX Center
3
800MHz TX High
4
900MHz RX/TA Low
5
900MHz RX/TA High
6 reference level adjustment (Analog Wide 5k, Analog Wide 4k)
Maximum Deviation / QT Deviation / DQT Deviation / LTR Deviation / DTMF Deviation / MSK Deviation
<6 points>
Tuning No.
Name
1
800MHz TX Low
2
800MHz TX Center
3
800MHz TX High
4
800MHz RX/TA Low
5
800MHz RX/TA Center
6
800MHz RX/TA High
1-32 (No.RA070<Rev.001>)
] button while the transceiver
] button to write tuning data through
AST
256
Adjustment value
(1~4096)
Proper value guide
(When the frequency
adjustment is necessary,
or
is displayed.)
Adjustment item
Display
800M TX L
800M TX C
800M TX H
900M RX/TA L
900M RX/TA H
Display
800M TX L
800M TX C
800M TX H
800M RX/TA L
800M RX/TA C
800M RX/TA H
4.3.2 Button operation
Button
Push
[Selector] -
[  ]
Adjustment value up
[  ]
Adjustment value down
[  ]
Auto adjustment start
[  ]
Wide 5k/Wide 4k/Narrow/
NXDN/DMR
[ Side1 ]
-
[ Side2 ]
-
[
]
Shift to panel test mode
[
]
To enter 5, 6 or 10
reference level adjustments
[
]
Writes the adjustment
value
[
]
Go to next adjustment
item
[AUX
-
(Orange)]
[PTT]
Transmit
[0] to [9]
-
and
[#],[ ]
RX (MHz)
TX (MHz)
806.050000
806.100000
815.550000
815.600000
823.950000
823.900000
935.050000
935.100000
939.950000
939.900000
RX (MHz)
TX (MHz)
806.050000
806.100000
815.550000
815.600000
823.950000
823.900000
851.050000
851.100000
859.950000
859.900000
868.950000
868.900000
Function
Hold (1 second)
Continuation up
Continuation down
Output tone pattern
change of balance
adjustment (A change is
possible only during
balance adjustment.)
-
-
-
-
Back to last adjustment
item (At the time of 5, 6 or
10 point adjustment:
Adjustment point change)
-

Hide quick links:

Advertisement

loading