Figure 11. Power/Alarm Connector - ADTRAN Total Access 372E Installation And Maintenance Manual

Active ethernet small business unit ont
Hide thumbs Also See for Total Access 372E:
Table of Contents

Advertisement

3. Remove the Power/Alarm Connector from the Electronics Module by pulling it directly
4. Remove the rubber grommet from the housing and route the wires through the rubber
5. To terminate the 2 Power leads and, and if needed, the 5 alarm status leads, cut wire to
6. Loosen each retaining screw and insert the wire into the appropriate slot (refer to
7. Tighten the retaining screws.
8. Reinstall the Euro-Connector in the Electronics Module.
9. Route these wires as shown above. If necessary, tie wrap them to the appropriate anchor
10. Reinstall the rubber grommet.
61287723G1-5B
from the module (see
Figure 11
grommet (see
Figure 11
Power/Alarm
Connector

Figure 11. Power/Alarm Connector

length and strip the insulation back 1/4 inch (0.64 cm).
on page 22).
point.
on page 23).
on page 23).
TOTAL ACCESS 372
1287722G1
TELEPHONE TROUBLESHOOTING:
1. Identify the bad line (POTS 1-8).
2. Plug any working phone into
the appropriate jack.
If the telephone works, the unit
is functioning normally.
If the telephone does not work,
contact your service provider.
3. Remove the telephone from the
POTS jack.
Power (Brown)
Installation
Table 4