Owners Manual for
Model FM100H Meter
GENERAL INFORMATION
To the Owner:
Please read the manual carefully before us-
ing your new meter. The information provided
will help you achieve years of dependable per-
formance and trouble-free operation.
SPECIFICATIONS
• Lightweight, corrosion resistant cast
aluminum body
• Burnished aluminum finish
• Registers up to 999.9 gallons (9,999 litres)
per delivery
• Totalizer registers up to 99,999 gallons
(999,999 litres)
• 50 psi (3.4 bar) maximum working pressure
• Large reset knob
• Operating range: 4-20 GPM (15-75 LPM)
• Inlet and outlet thread: 1" NPT or (1" BSPP)
Approved Chemicals for
Model FM100H Herbicide Meter
The GPI Herbicide Meter has been tested and
approved for most mini-bulk herbicides and
other chemicals that are compatible with alu-
®
minum, Viton
, thermoplastic polyester, stain-
®
less steel and Delrin
INSTALLATION
Thread pipe nipple into pump outlet. Using
bushing if required, install meter by applying
Teflon
®
tape to threads and turning meter onto
nipple.
NOTE: Meter outlet is marked on meter
housing.
Attach hose and nozzle to meter outlet using
®
Teflon
tape on all threads.
11/05
.
" A G r e a t P l a i n s Ve n t u r e s S u b s i d i a r y "
www.gpi.net
1-800-835-0113
W A R N I N G
GPI Herbicide Meter is approved to handle
only herbicides that are compatible with
meter materials. Meter is not approved for
gasoline, diesel and other fuels.
C A U T I O N
Always wear goggles, protective gloves,
and any other protection required for han-
dling herbicides. Observe all safety in-
structions for herbicides when handling
or servicing equipment.
CALIBRATION
NOTE: Verify your calibration. Use full flow
when calibrating. Meter accuracy is based
on proper calibration for each herbicide and
fluid temperature.
1. Fill pump, meter, hose and system by turn-
ing pump on, holding nozzle open, and fill-
ing a container until a full solid flow occurs.
Close nozzle.
2. Reset main meter dial to 000.0. Turn count-
er reset knob counterclockwise.
3. Fill a carefully measured 5 gallon container
(GPI Calibration Container P/N 116000-1)
up to marked point.
4. Note meter counter reading. If the meter
registers less than the container volume,
remove seal screw (111039-2) and turn the
calibration screw (111014-3) clockwise. If
main counter reading is more than con-
tainer volume, turn calibration screw coun-
terclockwise.
5. Continue calibration steps above until
counter reading is equal to measurement
container volume. Reinstall seal screw.
5252 East 36th Street North
Wichita, KS USA 67220-3205
TEL: 316-686-7361
FAX: 316-686-6746
Rev. A 921626-2

Advertisement

loading

Summary of Contents for GPI FM100H

  • Page 1 2. Reset main meter dial to 000.0. Turn count- Model FM100H Herbicide Meter er reset knob counterclockwise. The GPI Herbicide Meter has been tested and 3. Fill a carefully measured 5 gallon container approved for most mini-bulk herbicides and (GPI Calibration Container P/N 116000-1) other chemicals that are compatible with alu- up to marked point.
  • Page 2 See Assembly/Disassembly instructions and identify needed parts in a telephone call or for inspection of counter assembly and letter. GPI can also inform you of any special nutator disc assembly. Inspect and clean handling requirements you will need to follow...
  • Page 3 B. the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in accordance with the manufacturer’s operating instructions. To make a claim against this warranty, contact the GPI Customer Service Department at 316-686-7361 or 1-800-835-0113. Or by mail at: Great Plains Industries, Inc.
  • Page 4 “ A G r e a t P l a i n s Ve n t u r e s S u b s i d i a r y ” www.gpi.net 1-800-835-0113 GPI is a registered trademark of Great Plains Industries, Inc. © 2005 by GREAT PLAINS INDUSTRIES, INC., Wichita, KS. 11/05...