  • Page 1 Katherm QL ► Assembly, installation and operating instructions Keep these instructions in a safe place for future use! Issue12/20EN SAP No.1398084...
  • Page 3: Table Of Contents

    Table of contents 1 General ..........................5 1.1 About these instructions ......................... 1.2 Explanation of Symbols........................... 2 Safety............................ 6 2.1 Correct use.............................. 2.2 Limits of operation and use ........................2.3 Risk from electrocution!.......................... 2.4 Personnel requirements - Qualifications ....................2.5 Personal Protective Equipment ....................... 3 Transport, storage and packaging..................
  • Page 4 9.1 Operation of electromechanical control ....................30 10 Maintenance ......................... 32 10.1 Securing against reconnection ........................ 32 10.2 Maintenance Schedule:........................... 32 10.3 Maintenance work..........................33 10.3.1 Clean the inside of the unit ........................33 11 Faults ............................ 34 11.1 Fault table............................... 34 11.2 Start-up after rectification of fault ......................
  • Page 5: General

    Katherm QL Assembly, installation and operating instructions General About these instructions These instructions ensure the safe and efficient handling of this equipment. These instructions form an integral part of the equipment and have to be kept in the direct vicinity of the equipment and available to personnel at all times. All personnel must have carefully read through these instructions prior to commencing all work on the equipment.
  • Page 6: Safety

    Katherm QL Assembly, installation and operating instructions Safety This section provides an overview of all important safety aspects to ensure optimum protection of personnel as well as safe and trouble-free operation. In addition to the safety instructions in these operating instructions, the valid safety, accident pre- vention and environmental protection regulations must be observed for the area of use of the unit.
  • Page 7: Limits Of Operation And Use

    Katherm QL Assembly, installation and operating instructions Limits of operation and use Limits of operation Min./max. water temperature °C 4-90 Min./max. air intake temperature °C 6--40 Min./max. air humidity 20-60 Min. operating pressure bar/kPa Max. operating pressure bar/kPa 10/1000 Min./max. glycol percentage 0-50 Tab. 1: Limits of operation Operating voltage...
  • Page 8: Risk From Electrocution

    Katherm QL Assembly, installation and operating instructions IMPORTANT NOTE! Danger of frost in cooling mode! There is a risk of the heat exchanger freezing when used in unheated rooms. Make sure that the unit is equipped with a frost protection sensor and/or thermostat in this case. IMPORTANT NOTE! Warning of misuse! In the event of misuse, as itemised below, there is a danger of limited or failing operation of the unit.
  • Page 9: Personnel Requirements - Qualifications

    Katherm QL Assembly, installation and operating instructions Personnel requirements - Qualifications Specialist knowledge The installation of this product requires specialist knowledge of heating, cooling, ventilation, installation and electrical engin- eering. This knowledge, generally learned in vocational training in one of the fields mentioned above, is not described separ- ately.
  • Page 10: Transport, Storage And Packaging

    IMPORTANT NOTE! Warranty claims can only be made within the applicable period for complaints. (More information is avail- able in the T&Cs on the Kampmann website) IMPORTANT NOTE! 2 people are needed to transport the unit. Wear personal protective clothing when transporting the unit.
  • Page 11: Storage

    Katherm QL Assembly, installation and operating instructions Storage Store packaging under the following conditions: Do not store outdoors. Store in a dry and dust-free place. Store in a frost-free place. Do not expose to aggressive media. Protect from direct sunlight. Avoid mechanical vibrations and shocks.
  • Page 12: Technical Data

    Katherm QL Assembly, installation and operating instructions Technical data Unit Katherm QL Model QL 300 QL 300 QL 350 QL 350 Trench width [mm] Trench height [mm] Trench length [mm] 700 - 2700 700 - 2700 700 - 2700 700 - 2700 Number of connection spig- 1 - 5 1 - 5...
  • Page 13: Construction And Function

    Katherm QL Assembly, installation and operating instructions Construction and function Overview Fig. 1: Katherm QL at a glance Roll-up grille Air guide roller Convector Heating air inlet shaft Supply air spigot Air slider Flow with valve and actuator, ½“ Return with return fitting, ½“ Connection cover Brief description Katherm QL supplies the room with displacement air, guaranteeing a pleasant indoor climate.
  • Page 14: Installation And Wiring

    Katherm QL Assembly, installation and operating instructions Installation and wiring Requirements governing the installation site Only install and assemble the unit if the following conditions are met: Make sure that the wall/ceiling is sufficiently load-bearing to take the weight of the unit (Technical data [} 12]). Make sure that the unit is securely suspended/standing.
  • Page 15 Katherm QL Assembly, installation and operating instructions 6.2.1 Installation steps for Katherm QL...
  • Page 16 Katherm QL Assembly, installation and operating instructions Overall length...
  • Page 17 Katherm QL Assembly, installation and operating instructions...
  • Page 18 Katherm QL Assembly, installation and operating instructions...
  • Page 19: Installation

    Katherm QL Assembly, installation and operating instructions Installation Fit a thermoelectric actuator as follows if a thermoelectric Permitte shut-off valve is fitted: Place the thermoelectric actuator and manually tighten the union nut. Pull the electrical cable through the openings provided on the unit to the electrical junction box.
  • Page 20: Connection To The Pipe Network

    Katherm QL Assembly, installation and operating instructions 6.3.1 Connection to the pipe network The flow and return connections are located as standard on the left side of the trench underneath the cover panel. Use the punched pipe openings on the room side for the water-side connection. The convectors have a Eurocone valve connection. Proceed as follows when connecting up the unit's hydraulic pipework: Shut off the supply line from the heating medium.
  • Page 21 Katherm QL Assembly, installation and operating instructions Connection dimensions width 300 mm, height 150 mm Cross-section Front view Top view with valve kit (optional) Window side Top view Room side Connection dimensions width 300 mm, height 180 mm Cross-section Front view Window side Top view with valve kit (optional) Top view...
  • Page 22 Katherm QL Assembly, installation and operating instructions Connection dimensions width 350 mm, height 150 mm Cross-section Front view Window side Top view with valve kit (optional) Top view Room side Connection dimensions width 350 mm, height 180 mm Cross-section Front view Window side Top view with valve kit (optional) Top view...
  • Page 23: Electrical Connection

    Katherm QL Assembly, installation and operating instructions Electrical connection Connection (*00) Note these points in the following Katherm QL wiring diagrams: Comply with the details on cable types and cabling with due consideration of VDE 0100. Without *: NYM-J. The requisite number of wires, including protective earth, is stated on the cable. Cross-sections are not stated, as the cable length is involved in the calculation of the cross-section.
  • Page 24: Cabling Of Katherm Ql (*00), Actuation By Room Thermostat, Type 146904

    Katherm QL Assembly, installation and operating instructions Cabling of Katherm QL (*00), actuation by room thermostat, type 146904...
  • Page 25: Cabling Of Katherm Ql (*00), Actuation By Room Thermostat, Type 146927

    Katherm QL Assembly, installation and operating instructions Cabling of Katherm QL (*00), actuation by room thermostat, type 146927...
  • Page 26: Cabling Of Katherm Ql (*00), Actuation By Clock Thermostat, Type 146910

    Katherm QL Assembly, installation and operating instructions Cabling of Katherm QL (*00), actuation by clock thermostat, type 146910...
  • Page 27: Cabling Of Katherm Ql (*00), Actuation By Clock Thermostat, Type 146933

    Katherm QL Assembly, installation and operating instructions Cabling of Katherm QL (*00), actuation by clock thermostat, type 146933...
  • Page 28: Cabling Of Katherm Ql (*00), Actuation By Building Automation System

    Katherm QL Assembly, installation and operating instructions Cabling of Katherm QL (*00), actuation by building automation system 2-pipe heating...
  • Page 29: Pre-Commissioning Checks

    Katherm QL Assembly, installation and operating instructions Pre-commissioning checks Check before initial commissioning whether all necessary conditions have been met so that the unit can function safely and properly. Structural tests Check that the unit is securely standing and fixed. Check the horizontal installation/suspension of the unit.
  • Page 30: Operation

    Katherm QL Assembly, installation and operating instructions Operation Operation of electromechanical control Room thermostat, type 194000146904 Room thermostat in a flat surface-mounted housing, with thermal feedback 230 V, white, temperature setting range 5 - 30 °C, temperature range limit- ation is possible Protection class IP 30.
  • Page 31 Katherm QL Assembly, installation and operating instructions Electronic clock thermostat, type 194000146910 Clock thermostat 230 V / 50 Hz in an attractive white surface-mounted housing with electronic 2-point room temperature control and digital weekly timer Power reserve approx. 4 hours, party switch, switching status display with mode switch, Automatic/Day/Night/Off, adjustable switching difference Temperature adjustment range 10-30 °C Night setback 2-10 K...
  • Page 32: Maintenance

    Katherm QL Assembly, installation and operating instructions Maintenance 10.1 Securing against reconnection DANGER! Risk of death by unauthorised or uncontrolled restart! Unauthorised or uncontrolled restarting of the equipment can result in serious injury or death. Before restarting, ensure that all safety devices are fitted and working properly and that there is no haz- ard to humans.
  • Page 33: Maintenance Work

    Katherm QL Assembly, installation and operating instructions 10.3 Maintenance work 10.3.1 Clean the inside of the unit Check all elements that come into contact with air (internal surfaces of the unit, outlet elements etc.) for dirt or deposits dur- ing maintenance and use a commercially available product to remove. Loosen screws in the cover.
  • Page 34: Faults

    Katherm QL Assembly, installation and operating instructions Faults The following chapter describes possible causes of faults and the work needed to rectify them. Should faults occur frequently, shorten the maintenance intervals in line with the actual loading on the unit. Contact the manufacturer with any faults that cannot be rectified using the following informatio.
  • Page 35: Start-Up After Rectification Of Fault

    Katherm QL Assembly, installation and operating instructions 11.2 Start-up after rectification of fault After correction of the fault, carry out the following steps to re-start: 1. Make sure that all maintenance covers and access openings are sealed. 2. Switch off the unit. 3.
  • Page 36: Certificates

    Katherm QL Assembly, installation and operating instructions Certificates...
  • Page 37: 141_Eu_Konformitätserklärung_Katherm_Nk_Ql_Id.pdf

    EU-Konformitätserklärung EU Declaration of Conformity Déclaration de Conformité CE Deklaracja zgodności CE EU prohlášení o konformite KAMPMANN Wir (Name des Anbieters, Anschrift): GMBH & Co. KG Friedrich-Ebert-Str. 128-130 We (Supplier’s Name, Address): 49811 Lingen (Ems) Nous (Nom du Fournisseur, Adresse): My (Nazwa Dostawcy, adres): My (Jméno dodavatele, adresa):...
  • Page 38 Following the provisions of Directive: Conformément aux dispositions de Directive: Zgodnie z postanowieniami Dyrektywy: Odpovídající ustanovení směrnic: 305/2011/EU Bauproduktenverordnung Hendrik Kampmann Lingen (Ems), den 01.09.2020 ___________________________________ Ort und Datum der Ausstellung Name und Unterschrift des Befugten Place and Date of Issue Name and Signature of authorized person Lieu et date d’établissement...
  • Page 39: Table

    Katherm QL Assembly, installation and operating instructions Table Tab. 1 Limits of operation..............................7 Tab. 2 Operating voltage..............................7 Tab. 3 Water quality ................................7...