12. TECHNICAL DATA

Mains voltage
3~ 50 / 60 Hz
Rated power (U1=400V)
TIG
TIG
MMA
MMA
Connection cable
Fuse
Welding current range
TIG DC
AC
MMA
Maximum load (T=40 °C)
TIG AC
MMA DC
Maximum load (T=20 °C)
TIG AC
MMA DC
Open circuit voltage
(AC and DC)
Frequency of AC
fixed /
adjustable*)
Efficiency
Power factor
Open circuit power
Storage temperature range
Operating temperature range
Temperature class /
Degree of protection
– – – –
400 V ± 10 %
– – – –
60 % ED
350 A / 11,7 kVA
100 % ED
280 A / 8,2 kVA
60 % ED
350 A / 15,7 kVA
100 % ED
280 A / 11,2 kVA
4 x 2,5 mm
S - 5 m
2
400 V
20 A delayed
3 A / 10 V...350 A / 24 V
10 A / 10 V...350 A / 24 V
10 A / 20 V...350 A / 34 V
60 % ED
350 A / 24 V
100 % ED
280 A / 21,2 V
60 % ED
350 A / 34 V
100 % ED
280 A / 31,2 V
100 % ED
310 A / 22,4 V
80 % ED
350 A / 34 V
100 % ED
300 A / 32 V
70 V DC
60 Hz / 50 ... 200 Hz
80 % (350 A / 34 V)
0,9 (350 A / 34 V)
18 W
-40 ... +60 °C
-20 ... +40 °C
B (130 °C), H (180 °C) /
IP23S
26
© Kemppi Oy 2021
EMC class
External dimensions
length
width
heigh
Weight
Max liquid pressure of cooling
unit
Rated power of cooling unit
*) Adjustable with MINILOG- and PULSE panels.
The products meet conformity requirements for CE marking.
MasterTig ACDC 3500W
A
690 mm
260 mm
870 mm
74 kg
350 kPa
1300 W