Create A New Batt.m - Flash N61e Instructions Manual

Quick charger, discharger, balancer for li-po li-ion, li fepo4(a123), ni-cd, ni-mh, lead-acid up to 10 amp charge, 3 amp discharge convenient 'function' option fast/ std / slow / stg / cyc / manu
Table of Contents

Advertisement

N61e V1.0 or Higher
For lithium or Lead-Acid type, the charge mode is CCCV. During working at
CV, there are 3 icons indicating the state of charge of the pack. The first state
shows 'A', just CV processed recently. The second shows 'b', as operating
currents decrease further, and the batteries have been charged more than 90%
of capacity. When it shows ', the pack will be charged more than 95% of
it's capacity. In that case, to save time, you can interrupt the charging
operation and take the pack away for use.
For NiCd or Ni-MH type, the charge mode is CC (+Trickle). You can start up
or stop the Trickle function at SYSTEM PARAMETER. During trickling, the
screen shows 'Trk'.
No matter what type the pack is, you can re-set the operating current during
charging/discharging on constant current. On this page, enter to edit function,
and select the desired value, then re-press the dial to confirm. The operating
current will be renewed soon.
On page 2, the screen shows the input
voltage and the temperature of optional
sensor. If you disconnect the sensor, it
displays 'NO TEMP'.
It's highly recommended to use the temperature sensor for detection
during charge/discharge. You can program the cut off temperature value
and its units at SYSTEM PARAMETER.
On page 3, for lithium type, the screen will
display the balance information.
For NiCd or Ni-MH type, the screen will
display the PEAK voltage and the current '-△
V'. The preset value is indicated in the
bracket.

CREATE A NEW BATT.M

C
INPUT:
TEMP:
PEAK V:
-△V(48):
16/23
15.094V
25C
Page.2
7.200V
12mV